Braun NUVL855R service manual Lift will GO UP with

Page 18

Troubleshooting Diagnosis Chart

FUNCTION

 

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

4.11

Barrier Down LED (D29) illuminated

Barrier is down, barrier release pin partially out

4.00

 

 

or Barrier Down switch out of adjustment. Make

 

 

adjustments as necessary.

LIFT WILL

 

 

 

GO UP WITH

)XOO2XW/(' ' QRWLOOXPLQDWHG

&KHFN)XOO2XWVZLWFKIRUSURSHURSHUDWLRQDGMXVW-

OVERRIDE

 

 

ment. Replace or adjust as necessary.

SWITCH BUT

 

 

 

 

 

NOT WITH

4.13 Remote not working properly

Check for Up LED D20 when hitting Up button on

REMOTE

 

 

remote. Check battery in remote. Replace bat-

 

 

 

 

 

 

tery/remote as necessary.

 

 

 

 

 

 

 

 

5.00

5.11

Hydraulic Down valve bad

Check for power on valve “T” wire going to so-

LIFT WILL

 

 

lenoid when pushing manual override or remote

NOT GO

 

 

button. Replace if necessary.

DOWN WITH

5.12

Dirty Down valve (clogged)

)OXVKYDOYHE\SXVKLQJPDQXDORYHUULGHXSDQG

MANUAL

OVERRIDE

 

 

down buttons at same time for 4 to 5 seconds

OR WITH

 

 

several times.

REMOTE OR

 

 

 

GOES DOWN

 

 

 

SLOWLY

 

 

 

OR DRIFTS

 

 

 

DOWN BY

 

 

 

ITSELF

 

 

 

 

 

 

 

 

 

6.00

)XOO2XW/(' ' QRWLOOXPLQDWHG

&KHFNIRUSURSHURSHUDWLRQRI)XOO2XWVZLWFKZLWK

LIFT WILL GO

 

 

LED on P.C. board. Replace or adjust switch as

DOWN WITH

 

 

necessary.

OVERRIDE

 

 

 

BUT NOT WITH

 

 

 

REMOTE

 

 

 

 

 

 

 

 

 

 

 

 

7.11

Defective self-reset breaker

Check for power through 20 amp self-reset breaker.

 

 

 

Replace if necessary.

7.00

7.12 No power on terminal 9

&KHFNYHKLFOH'RRU)XOO2SHQVZLWFKDQGZLULQJ

 

 

 

LIFT WILL NOT

7.13

Interlock circuit incomplete

9HULI\LQWHUORFNLQVWDOODWLRQ

GO OUT WITH

 

 

 

OVERRIDE OR

7.14 Poor plug connections

Check harness connections A1, A2, B1 and B2

REMOTE

 

 

 

 

7.15

Bad in/out motor

Check power at motor. Replace motor if necessary.

 

7.16 Bad power and ground

See 1.00

 

 

 

 

 

 

 

)DXOW\%HORZ6WRZVZLWFK%HORZ

Check for proper operation of Below Stow switch.

8.00

 

Stow LED (D24) not illuminated

 

 

 

 

LIFT WILL NOT

8.12

Pressure LED (D18) illuminated

Remove weight from platform. See Platform

STOW WITH

REMOTE

 

 

Sense Calibration on page 5.

 

 

 

 

Page 16

Image 18
Contents Series Warranty and Registration Instructions CongratulationsContents Lift Housing Lift TerminologySwitch and Sensor Locations Certification Checklist Diagnostic Procedures EHORZÁRRUOHYHOAdjustments and Calibration $GMXVWPHQW3URFHGXUHVFloor Level and Inner Roll Stop Adjustments Terminal Strip and Door OperatorsInner Roll Stop Adjustment UROOVWRSUHVWVRQWKHÁRRU QRWDG- just the in- ner roll stop Inner Roll Stop Occupied Sensor Adjustment Lubrication Diagram Maintenance and Lubrication Schedule When servicing the lift at the recommended intervals1500 4500 Cycles Troubleshooting Diagnosis Chart Function Possible Cause RemedyLift will GO UP with Switches Contact Removal Wiring Schematic BoardHydraulic Parts List Qty DescriptionHydraulic Diagram Pump Module Parts List Qty DescriptionPump Module Diagram Unfold Modulefor Complete Lift Exploded ViewRepair Parts List Qty DescriptionLift Housing Detail Exploded View Lift Carriage Detail Exploded View Lift Platform Detail Exploded View Providing Access to the World CJKA-**G