IBM XM60 manual Install the battery, Remove the battery from spare battery charging well

Page 9

XM60 User Manual

Install the battery

IMPORTANT Battery Warning!

CAUTION: Use only Janam-approved batteries.

There is the risk of explosion if battery is replaced by an incorrect type.

Always dispose of used batteries according to the instructions.

1.To access the battery compartment, turn the locking screw counterclockwise to open the latch and remove battery cover.

2.Position the battery lift strap against the back of battery well, ensuring tab extension is on left side.

3.Place a Janam Lithium-ion rechargeable battery in and snap into place.

4.Replace the battery cover by positioning the top prongs first and sliding into place. Tighten locking screw by turning clockwise.

To charge the battery:

Important Note: The main battery charges the backup battery in the XM60. Once the main battery is fully charged, do not remove it from the unit for 24 hours. If the battery is removed during this period, the device cannot maintain any user data.

To charge the battery using the USB syncing/charging cable or serial charging cable:

1.Connect the power supply to the USB syncing/charging cable or serial/syncing charging cable.

2.Connect snap-on end of USB syncing/charging cable or serial/syncing charging cable to bottom of XM60, making sure the word TOP on the connector faces front.

3.Insert country-specific AC plug, and plug in the power supply.

4.The LED will illuminate to confirm connection (orange indicates charging, green indicates fully charged and red indicates fault).

5.The battery is fully charged in approximately two hours.

To charge the battery using the single-slot or four-slot cradle:

1.Connect the power supply to the cradle.

2.Connect the line cord to the appropriate power supply.

3.Plug in the power supply.

4.Insert the XM60 into the cradle. Important: Proper insertion is required to ensure connection. Be sure to insert the device as follows:

Place the XM60 in cradle well (seating the device without trying to join connectors).

Tilt-rotate the XM60 forward (bringing the top end of the unit forward) as you apply downward pressure to fully insert in cradle well, joining connectors.

5.The LED will illuminate to confirm connection (orange indicates charging, green indicates fully charged and red indicates fault).

6.The battery is fully charged in approximately two hours.

Remove the battery from spare battery charging well

Do not force-pull the battery from charging well. Follow these instructions to remove the battery:

1.While gently holding down with thumb, slip index finger down against the battery so that you feel the edge where the battery meets the cradle.

2.Press down and forward with index finger to lift battery edge.

Turn on the XM60

The first time the device is turned on, calibrate the screen using the stylus. The stylus is located on the back of the device. To calibrate, simply follow the on-screen instructions and remember to save your settings.

Note: If your XM60 came pre-loaded with a custom software application, a welcome utility may not appear. If this happens, follow the on-screen instructions.

Janam Technologies LLC

2-2

Image 9
Contents XM60 User Guide Contents Beam Information Hardware features IntroductionAbout the Janam XM60 Specifications LCD Hardware overviewBattery Compartment Update your desktop software Attach the hand strap Recommended host computer configuration/requirementsGet Started Unpack your Janam XM60Remove the battery from spare battery charging well Install the batteryImportant Battery Warning To charge the batteryUnderstanding the desktop Command barTo install the latest ROM To download the correct BIN fileAccept the terms and conditions, and go to PartnerZone Description Resolution Explanation To troubleshoot during ROM updateReset the XM60 To soft resetTo hard reset Barcode scanning demonstration and setup Select setup symbology configBarcode Scanning Enable the ScanWedge feature Unlock 2D scanningGo to MS Windows icon programs XM60 applications ScanWedge Enter your five-digit key code unlock Enable ScanCapture featurePress X to close the screen To take a single imageTo use intelligent capture Go to settings intel img Enter image’s name and select folderTo use continuous preview Click cont or continue button Janam Technologies LLC Janam Technologies LLC Locate front panel controls Set up your Janam XM60Locate back panel components Tap versus clickTo update the regional settings Use the regional and language featuresOpen applications To open an application Tap the MS Windows icon programsRemove applications Enter dataCustomize Set the date, time and time zone preferences Format numbers, currency, time and dateNumber Currency Time Date Set the display properties To change the appearanceTo change backlight preferences Tap backlight tab Change keypad options Select volume and enable soundsSet internet options To change key size on soft keyboardConnection Security PrivacyAdvanced Popups Janam Technologies LLC Enter Data To access the onscreen keyboardUse the stylus or touch screen with the onscreen keyboard To close the onscreen keyboardUse the barcode scanner Import dataSet up/delete a partnership Exchange and update Data Using ActiveSyncCreate a user profile Enter identification, notes and network ID informationSelect yes in the select number of partnerships screen To delete a partnership On your PC, select start programs ActiveSync Click no nextChoose copy files and select destination folder on your PC Partnership settings To change partnership connection settingsMake changes OK Wireless Configuration Wireless local area network accessTap enable Enter ESSID, authentication and encryption Start Bluetooth manager Bluetooth ManagerBond Wizard Scan Device WizardTo use Scan Device Wizard Tap finishTo send files Send filesFile browser Bluetooth ActiveSyncTo use the file browser Input PIN numberChoose Bluetooth ActiveSync on your XM60 device To use Bluetooth COM service create a BT virtual COM port To check what service the scanned BT device supportsClick on property icon To check Bluetooth chip setting Go to tools about Janam Technologies LLC Beam Information Turn beaming on/offClick on or off OK To beam a file or application Beam informationRegulatory and safety approvals Regulatory and MaintenanceParameter Specification FCC and Canadian compliance XM Series batch terminalXM Series RF Terminals with 802.11b and/or Bluetooth Care and cleaning of terminals RF, regulatory and safety approvalsFor European Community users Waste electrical and electronic equipment Weee informationGeneral Information Battery Warning