Lucent Technologies 7400B manual Installation

Page 16

DEFINITY Communications System

CHAPTER 2: INSTALLATION

7400B Data Module

 

 

User’s Guide

Page 2-5

 

 

 

About the Terminal Device The 7400B Data Module operates with any asynchronous data terminal device that has an EIA-232-D (or RS-232-C) serial port connector. If you are using a PC as your terminal, you will need a suitable data communications software package.

Also, you must set the appropriate configuration options before connecting the 7400B Data Module to a printer or plotter. To do this, connect a data terminal or PC to Port 1 of the data module, change the necessary configuration parameters, remove the data terminal or PC, and then connect the printer of plotter. The configuration parameters used for this type of operation are described in Chapter 4, "Operation and Configuration," in a section titled “Remote Site Use.”

EIA-232-D cables and data communications software packages are described in the following paragraphs.

Selecting an EIA-232-DSelect an EIA-232-D with a male connector at one end to mate with the

CablePort 1 connector of the 7400B Data Module, and a connector of the appropriate "gender" at the other end to mate with the communications port of your terminal device.

Note: Cables with the earlier RS-232-C designation will also work.

The most common EIA-232-D cables are supplied with a male connector at both ends. If you have this type of cable and the EIA-232- D port on your terminal device is a male connector, you can use a cable adapter commonly referred to as a “gender changer”. Otherwise, obtain an EIA-232-D cable that has the appropriate gender connector at each end to fit your application needs.

Selecting DataThe purpose of data communications software is to allow your PC to Communications Software operate as an asynchronous data communications terminal. Of the many

software packages available, all perform essentially the same functions, but often in significantly different ways.

If you do not already have a communications software package, consult with an experienced user for advice on selecting software to suit your data communications needs. The following, though not required, are a few helpful features that you may wish to look for in the software you select:

Terminal mode. Also called local mode or chat mode, this feature allows you to issue commands to the 7400B Data Module. The software that you select must have some form of terminal mode.

Dialing directory. This feature allows you to store several frequently called numbers, often along with configuration of the data options needed for completing the connection.

Image 16
Contents AT&T 7400B Data Module To Order Copies of this Manual Contents Preface about this Guide 1C-1C-2C-5C-8 Typographical ConventionsOrganization of this GuideTroubleshooting. Describes procedures for Appendix C Application Notes. Contains notes on how toAppendix D Quick-Reference Summaries. Contains quick RelatedIntroduction External Features Front PanelConnector Description Front Panel LED Indicator DescriptionsRear Panel Connector Descriptions Rear PanelPower Supply Unit Software HardwareRequirements Typical Standalone Installation Typical Installation with Telephone Installation Installation Selecting DIP-Switch Options With/Without Telephone Option SW1-1Data Metering Option SW1-5 InstallationMake Busy on Local Loop Option SW1-8 Factory-default Option DIP Switch SettingsTelephone SW1-1 Data Metering SW1-5Accessing the Hardware Option Switches Connecting the EIA-232-D Cable Connecting the Power SupplyPower-Up Self-Test If YOU are Using a PCIf YOU are Using a Dedicated TerminalLine or data mode Operating ModesCharacter Formats Data Bits Parity Stop BitsEssential AT Commands AT Command Subset AT Command DescriptionMore AT Command Subset Contd ConnectBusy Sample ON-LINE Session Starting the SessionNo Carrier Selection +++Operation and Configuration Configuration ParametersCommand Line Action Issuing Commands Command Line PrefixCommand Buffer Command Line Set UpAts3= ddd Enter Command AcknowledgementVerbose Form Numeric Description Result CodesFrom Data Mode to Command Mode and Back Dialing a Number Multiple CharactersFollowing is an example Commands for Using Stored Telephone Numbers At&z m=nnn...n EnterConfiguration Recall ResetRemote Site USE At&f Enter HOW to USE this ChapterSymptom Problem Solution PBXCheck Speed LED At&d2 Enter Terminate the local loopback test by typing Atq0 o Enter Atx4 Enter Appendix a AT Command SET LabelDescriptionContd Escape sequence Immediate None Arguments none CommandAArguments none Registernone Examplea CommandD Command Function Switch hook control Command Function Type Arguments Register Example Comments Ato EnterAtv Enter A-10 User’s Guide Reset and recall a stored profile Data Carrier Detect DCD options Data Terminal Ready DTR options Command&F Arguments none Registernone ExampleAt&t3 Enter see comment At&v Enter Command&Y Registernone ExampleAt&z2=555-1212 Enter 055 Description Range Values Comments See Also Storable Register DescriptionStorable Comments From a data terminal Register S6 not used Register S8 not used S9 not used Register S11 not used Register S13 not usedRegister Description Range Values Storable Comments See Also Register S15 not usedRegister S17 not used Values Storable Register S19 not used S20 not usedRegisterS21 Range of Values Storable Comments See AlsoBits 0 and 1 not used default = 2, see comment Register S24 not used Register S27 not used PBX Application Notes PC Applications Guide AT&T 7400B Data Module PC Application Guide, ordering numberConfiguring the Software Procomm PlusSelect Modem Options Select Result MessagesSelect Save Setup Options Placing a CallDisconnecting Call C-4Placing a Call Directly Relay GoldSelect Call a Host Directory AttmailDisconnecting a Call Press Esc to return to the Online menu as shown belowCrosstalk Select the letter next to Hayes Smartmodem all modelsSelect the baud rate that you will use most often Bye Enter Appendix D QUICK-REFERENCE Summaries Table D-1 AT Command SET Command DescriptionSr=n Table D-1 AT Command SET Contd Register Description Range/Unit Table D-2 S-REGISTER SummaryConnected Table D-3 Result CodesTable D-4 FACTORY-DEFAULT Configuration Parameter Value AT CommandR e Table D-4 FACTORY-DEFAULT Configuration Contd Parameter Value RegisterPin Circuit Direction Function Table D-5 EIA-232-D PIN AssignmentsAscii Control KEY Value Character Table D-6 Ascii Character SETTable D-6 Ascii Character SET Contd Glossary Glossary Script files. See command files Index DTE, see Data Terminal Device DTR lead Data MeteringRear panel, 1-4Remote site use AT&T Important Safety Instructions Page Important Installation Safety Instructions