Bandwidth Select (Only Canada models)

All US models are compliants with the narrowbandwith FCC regulation.

Default setting for Bandwidth Select depends on the specific frequency and channel. Some frequencies have selectable channel spacing, which must match with other radios for optimum audio quality.

For details, refer to Frequency and Code Charts section.

Time-Out Timer

When pressing the PTT button, transmissions will be terminated after a preset time of continuous transmitting. The default setting is 60 sec and can be changed using the CPS.

Scramble

The Scramble feature makes transmissions sound garbled to anyone listening without the same code. Scramble default value is OFF. The Scramble feature must be programmed to SB1 or SB2.

Power Select

 

Power Select allows you to select between

 

high and low transmission power per channel.

 

The power levels for RM Series toggle

 

between 2W and 1W.

 

Call Tones

 

Call Tones feature allows you to transmit an

 

 

audible tone to other radios on the same

PROGRAMMING

channel and alerting them that you are about

to talk or alerting them

FEATURES

without speaking. The call tones feature must

 

be programmed to SB1 or SB2 and 1 of 3 pre-

 

recorded tones selected

 

Reverse Burst

 

Reverse Burst eliminates unwanted noise

 

(squelch tail) during loss of carrier detection.

 

You can select values of either 180 or 240 to

 

be compatible with other radios. Default is

 

180.

 

Notes: Some of the features available with the CPS software may vary depending on the radio model.

47 English

Image 44
Contents RM Series/Séries RM Two- Way Radios Radios bidirectionnelles Page Contents Contents Use and Care TroubleshootingMotorola Limited Warranty for Safety SafetyIntroduction Package ContentsIntroduction US and Canada 1-888-390-6456 on your TTY Text Telephone FCC Licensing Information Interference InformationFCC Licensing Information Canada Licensing Information Canada LicensingGeneral Information License ApplicationBatteries Chargers Safety Information Batteries and Chargers Safety InformationOperational Safety Guidelines Parts of the Radio Radio OverviewRadio Overview Side Button 2 SB2 Push-to-Talk PTT ButtonSide Button 1 SB1 Frequency Transmit Number Battery Features About the Li-Ion BatteryBattery Recycling and Disposal BatteryInstalling the Lithium-Ion Li-Ion Battery Removing the Lithium-Ion Li-Ion BatteryPower Supply and Drop-in Tray Charger HolsterBattery Life Information Charging the Battery Charging with the Drop-in Tray Single Unit Charger SUCRadio Overview Drop-in Tray Charger LED Indicators Estimated Charging Time Radio Overview Adjusting Volume Getting StartedTurning Radio ON/OFF Selecting a ChannelReceiving a Call Getting StartedTalk Range Getting Started Radio LED Indicators Radio Status LED IndicationWith Compatible VOX Accessories HANDS-FREE USE/VOXSetting VOX Sensitivity Battery SaveReset to Factory Defaults Microphone GainEnd of Transmission Tone Roger Beep Tone Programming Features Advanced ConfigurationEntering Frequencies Values Programming FeaturesEntering Advanced Configuration Mode Reading Auto-Scan Values Saving SettingsReading CTCSS/DPL Values Programming Mode FAQ Return to Idle Programming Mode and start overEnter Programming Mode Example of Programming a Code Example of Programming Auto-Scan Example of Programming Active Channels Other Programming Features Scan Editing Scan List Nuisance Channel DeleteCPS Computer Programming Software Time-Out Timer Power SelectScramble Call TonesCloning Radios Cloning with a Multi Unit Charger MUCWhen ordering the MUC, please refer to P/N PMLN6384A CPS and Cloning Cables Optionals Operating Instructions What To Do if Cloning Fails Cloning using the CPS Computer Programming Software Troubleshooting TroubleshootingRange. Check for clear line of sight to improve transmission Try This VOX feature might be set to OFF USE and Care USE and CareFrequency and Code Charts RMU2043 UHF Default Frequencies ChartRM UHF 4CH Radios Default Frequencies RMU2043 Frequency and CodeRMU2040 UHF Default Frequencies Chart RM UHF 4 CH Radios Default Frequencies RMU2040RMM2050 Murs Default Frequencies Chart Frequency and Code Ctcss and PL/DPL Codes Ctcss CodesPL/DPL Codes 654 129 Customized PL 445 112 662 130 139 190 Products and Accessories Motorola Limited Warranty for the United States and CanadaWhat Does this Warranty Cover? Warranty ExclusionsHOW to Obtain Warranty Service or Other INFORMATION? SoftwareWHO is COVERED? Software Copyright NoticePatent Notice Export LAW AssurancesAudio Accessories Battery AccessoriesAccessories Carrying CablesChargers 68012009071