Appendix A — Wiring Requirements
Note the following cabling requirements before connecting the equipment. If these limits (which are the same ones that apply to our current SPIRIT System) are exceeded, the SPIRIT Attendant ConnecT/R may not work properly.
●The total wire length from the controller to the SPIRIT Attendant cannot exceed a total of 1000 feet of 24- gauge DIW
●If the SPIRIT Attendant ConnecT/R is installed outside the building where the controller is located, using exposed wiring
●If the SPIRIT Attendant will be in a building other than where the SPIRIT Attendant ConnecT/R is located, a Block Protector
must be installed by a qualified technician. Order an AT&T Model 4ClS (comcode
104386545). In addition, you will need a Building Entrance Protector, which can house up to six 4C1S Block Protectors. Order Model