STANDARD PROGRAMMING METHOD

System Options

For most installations the factory settings for the system will be appropriate. To customize the system, enter programming mode via telephone or keypad.

Use the programming worksheet supplied to log any system option changes prior to entering it into the system.

For each of the following steps, enter the Master Password and enter

Programming Mode (if the unit is not already in that mode). Exit

Programming Mode when all programming is complete.

System Display Language

The factory default language is English. Three other languages can be

SYSTEM DISPLAY LANGUAGE

PPN 38

selected as the language for the user and programming displays.

38#LANG#

NOTE: This step cannot be performed remotely through the

 

telephone.

 

LANG = SYSTEM DISPLAY LANGUAGE

NOTE: The system supports one display language at a time.

1 = ENGLISH

2 = SPANISH

1.

Press

2.

Choose a language:

3 = FRENCH

4 = PORTUGUESE

 

Enter 1 for English

FACTORY SETTING: ENGLISH

 

Enter 2 for Spanish

 

Enter 3 for French

 

 

 

Enter 4 for Portuguese

 

 

 

KEYPAD LOCKOUT COUNT

PPN 51

3.

Press

 

 

 

Keypad Lockout Count

51#COUNT#

The system counts the number of invalid Entry Codes entered at the

keypad. If the invalid entries exceeds the lockout count number, the

COUNT = NUMBER (1-9) OF INCORRECT ENTRIES

keypad is locked out for 90 seconds. The factory setting for the lockout

count is three. The lockout value can be from one to nine.

THAT WILL CAUSE A 90 SECOND LOCKOUT

1.

Press

FACTORY SETTING: 3 TRIES

 

 

 

2.

Enter the number for the lockout count (1-9).

 

 

 

 

ACCESS RELAY ACTIVATION TIME

PPN 52

3.

Press

 

 

 

Access Relay Activation Time

52#SECONDS#

The factory setting will cause the access relay to activate for 4 seconds.

The activation time can be set from 4-99 seconds to accommodate

 

 

different types of access control devices.

SECONDS = ACTIVATION TIME (04-99 SECONDS)

1.

Press

 

 

2.

Enter the time (in seconds) for access relay to stay activated (04-99)

FACTORY SETTING: 4 SECONDS

3.

Press

 

 

9

Image 9
Contents AE-100 Stand-alone Entry Code Data Resident Directory DataSystem Features Programming from the Keypad Standard Method Access to ProgrammingProgramming Over the Telephone Connecting with a TelephoneTelephone Audio Prompts Condition MethodProgramming Reference & Factory Defaults Multi-unit InstallationsPre-set Unit Numbers 02#LENGTH# 23#DIR#DIR#Resident Data Programming 33#CODE#CODE# 31#CODE#CODE#Stand-alone Entry Code Programming Adding a Stand-alone Entry Code51#COUNT# Access Relay Activation TimeSystem Options System Display Language62#CHIRP# Speaker Tone on Access Relay ActivationWelcome Display Text Automatic Telephone Answer77#CONTROL# Resident Control of Access Relay95#CALL-BACK# Maximum Visitor Talk TimeCopy Access Data Only from Master to Sub-units System Utility Commands30#SUB-UNITS#5# 34#SUB-UNITS#5#80#HOURS# Alternate Programming Section Local Programming Telephone Programming Alternate Programming ReferenceProgram a NEW TenantExisting Tenant Modify ANDirectory Entry Not AvailableFunction Code Local Programming Telephone Programming ADD a Access CodeSTAND-ALONE Delete aMaximum Visitor Access RelayTalk Time Keypad LockoutAutomatic On Access RelayTelephone AnswerExit Access CodesProgramming ModeRequesting Access with an Entry Code Requesting Access with a Visitor CallAE-100 Operation Resident Call-backResident’s Telephone does not ring when a visitor calls TroubleshootingSystem will not answer an incoming call Keypad will not activate a relayCopyright 2007 Linear LLC
Related manuals
Manual 24 pages 57.93 Kb

AE-100 specifications

The Linear AE-100 is an advanced sound reinforcement amplifier, renowned for its superior performance and cutting-edge technology. Designed for both professional and personal use, the AE-100 possesses features that appeal to audio enthusiasts and professionals alike, making it a versatile choice for various applications including live performances, home theaters, and installations.

One of the standout features of the Linear AE-100 is its high power output, which ensures clear and powerful sound delivery even in large venues. It typically boasts an impressive output of up to 100 watts per channel, allowing it to handle the demands of large speaker systems without distortion. This attribute makes the AE-100 suitable for dynamic audio environments, where precision and clarity are paramount.

The amplifier incorporates advanced protection circuitry, preventing damage from overheating, short circuits, or overloading. This protective technology enhances the longevity and reliability of the device, allowing users to perform confidently without worrying about equipment failure during crucial events.

The AE-100 also supports both balanced and unbalanced input options, providing versatility in connectivity. The balanced XLR inputs help reduce noise interference, particularly over long cable runs, while the unbalanced 1/4” inputs cater to a variety of equipment setups. This adaptability enables it to integrate seamlessly with a wide range of sound sources, from microphones to musical instruments and playback devices.

Moreover, the device features an intelligent cooling system that maintains optimal operating temperatures. With a design that prioritizes airflow and heat dissipation, the AE-100 can sustain extended periods of use without compromising performance, making it ideal for lengthy performances or all-day events.

The Linear AE-100 also boasts a sleek and modern design, featuring a user-friendly interface with clearly labeled controls for ease of operation. Its build quality reflects durability, designed to withstand the rigors of both touring and fixed installations.

In summary, the Linear AE-100 is a powerful and efficient amplifier packed with features that cater to the needs of audio professionals and enthusiasts. With its robust power output, advanced protection mechanisms, versatile connectivity options, and intelligent cooling system, it stands out as a reliable choice for anyone seeking high-quality audio performance. Whether for live sound applications or home audio systems, the AE-100 delivers exceptional sound quality and reliability.