nn– telephone number up to 16 digits to be stored. Refer to the table for other choices.
The number stored in parameter 2 is the number for the second group or the number for Night mode
Note: The switchover to Day/Night mode remains set in the unit even after line disconnection.
parameter | choice |
0 - 9 | 0 - 9 |
# | # |
∗ | ∗∗ |
Recall | ∗ # |
Pause | ∗ 0 |
5.2 Relay
|
|
|
|
|
|
|
|
Parameter | Value | Description | Default | Exam.1 | Exam.2 |
| |
|
|
|
|
|
|
| |
31 | r m | Relay mode | 1 | 1 | 2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
m – | relay mode [ |
|
|
|
| ||
m=1 | relay mode – relay will close on command or password for ss period (used for electrical locks, gate | ||||||
| opening, etc.) |
|
|
|
|
|
m=2 button mode – (activated by button press e.g. external bell).
|
|
|
|
|
| |
Parameter | Value | Description | Default | Exam.1 | Exam.2 | |
|
|
|
|
|
| |
32 | r hhhhhh | External access code in | - | 1212 | 1324 | |
DAY + NIGHT mode | ||||||
|
|
|
|
| ||
33 | r hhhhhh | External access code in | - | 2211 | 2211 | |
DAY mode | ||||||
|
|
|
|
| ||
34 | r hhhhhh | External access code in | - | 1122 | 1122 | |
NIGHT mode | ||||||
|
|
|
|
| ||
|
|
|
|
|
|
hhhhhh– password for relay closing from buttons [2 to 6 digits]
The 3 passwords are controlled by Day/Night; the combination is entered using the unit buttons. It is influenced by the setting of Relay mode and Day/Night switchover. When set to
Follow these rules when choosing password combination:
Select passwords carefully, to prevent their discovery from wear on buttons caused by frequent use.
Select the first password button from
Note: The switchover to Day/Night mode remains set in unit even after line disconnection.
|
|
|
|
|
|
Parameter | Value | Description | Default | Exam.1 | Exam.2 |
35 | aa | Internal access code | 55 | 55 | 55 |
|
|
|
|
|
|
|
|
|
|
|
|
aa– command from phone to relay closing [2 digits]
It is recommended to set the same command for Internal Access Code and End Call (parameter 43) aa=bb.
|
|
|
|
|
|
|
|
Parametr | Value | Description | Default |
| Exam.1 | Exam.2 | |
36 |
| ss | Relay closing time | 05 | 02 | 05 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
ss – | duration of relay closing [2 digits |
|
|
|
|