ENTRY SYSTEM MOUNTING

Pedestal Mounting

The RE-2 Entry System can be mounted with the Model GNC-1 (curb mount) or Model GNB-1 (burial mount) gooseneck pedestals.

1.Open the RE-2 case by removing the four security screws with the wrench provided (see Figure 1).

2.Use four security bolts and locking nuts to secure the backplate to the pedestal (see Figure 2).

Wall Mounting

The RE-2 Entry System can be mounted directly to a wall or fl at surface.

1.Open the RE-2 case by removing the four security screws with the wrench provided (see Figure 1).

2.Use the appropriate fasteners to secure the system’s backplate to the mounting surface. When mounting the system to a concrete wall, use concrete wedge anchors (see Figure 3).

REMOVE THE FOUR

SECURITY SCREWS

TO OPEN THE CASE

Figure 1. Opening the RE-2 Case

MOUNT REAR CASE

WITH SECURITY BOLTS

PEDESTALAND LOCKNUTS

MOUNTING

PEDESTAL

CAUTION! BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1" INSIDE THE REAR COVER OR ELECTRICAL DAMAGE MAY OCCUR

Figure 2. Pedestal Mounting

Recessed Mounting

The RE-2 can be mounted recessed using an accessory trim-ring. The trim-ring mounts in the wall and the cabinet attaches to the trim-ring.

Two trim-rings models are available to match the color of the RE-2 case:

For the RE-2N use trim-ring P/N ACP00915.

For the RE-2SS use trim-ring P/N ACP00917.

1.Identify the location of any studs in the wall.

2.Cut a 10-1/4” wide by 6-1/4” high rectangular hole between studs at the mounting location.

3.Install any additional mounting material required to provide surfaces inside the wall for attaching the trim-ring.

4.Place the trim-ring in the wall hole. Check for level, then attach the trim-ring with screws into the side tabs.

5.Drill the cabinet’s four self-drill mounting holes the appropriate size for the hardware.

6.Attach the cabinet to the trim-ring using self-tapping screws.

7.Route the wiring into the cabinet.

1 DETERMINE LOCATION FOR

2 MARK HOLE LOCATION

THE 10-1/4" x 6-1/4" MOUNTING HOLE

 

RECESSED

MOUNTING

6-1/4"

10-1/4"

3 CUT MOUNTING HOLE

4 INSTALL ANY SPACER

 

SHIMS TO ALLOW MOUNTING

ATTACH THE TRIM-RING

WITH SCREWS

DRILL 3/16" HOLES IN

5THE CABINET AT THE

WALL

MOUNTING

USE WEDGE ANCHORS FOR CONCRETE OR OTHER APPROPRIATE ANCHORS FOR DIFFERENT MATERIALS

CAUTION! BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1" INSIDE THE REAR CASE OR ELECTRICAL DAMAGE MAY OCCUR

PRE-MARKED LOCATIONS

6

ATTACH THE CABINET TO

 

THE TRIM-RING WITH

SELF-TAPING SCREWS

Figure 3. Wall Mounting

Figure 4. Recessed Mounting

5

Image 7
Contents RE-2 Features ContentsOperation Access MethodsSystem Features Product DescriptionInstallation Information Help Button Component LocationsTypical Gate Installation Wiring Wiring DiagramRecessed Mounting Entry System MountingPedestal Mounting Wall MountingTelephone Wiring Options Telephone WiringCommand Prefix for Multiple Units Multiple Unit InstallationsGate Control Control WiringDoor or Pedestrian Gate Control Optional Remote Antenna POWER, BATTERY, & Ground WiringPower Wiring Backup BatteryKeyswitch Installation Optional KeyswitchOptional Remote Keypad Optional Color Cctv Camera Camera InstallationProgramming with a Computer Programming AccessSystem Requirements Setting UP a Windows XP DIAL-UP Network Connection Remote Programming with a Telephone Programming with a Local Telephone or the Unit’s KeypadProgramming Control Programming ReferenceEntry Code Programming Basic System ProgrammingTelephone Programming Transmitter ProgrammingAdvanced System Programming Press Count Press Obstacle Facility IDPress Address Press Input TypeSpeakerphone Volume System AdjustmentsDigital Speech Volume RE-2 Operation Call Waiting Feature On/Off To Enter Programming ModeTo Exit Programming Mode & Save Changes Re-entering a Command After a MistakeDimension Drawing SpecificationsTroubleshooting Time Zones Programming WorksheetRelay # Time Zone Important Wireless Information Linear Limited Warranty