Linear RE-2 manual Programming with a Local Telephone or the Unit’s Keypad

Page 16

1.DOUBLE-CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW

2.CLICK "DIAL" TO START THE CONNECTION

3.THE MODEM WILL

DIAL THE NUMBER

4.ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-2 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT

5.THE RE-2 WILL

VERIFY THE USERNAME

AND PASSWORD

CONNECTING TO THE RE-2

6.AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS:

http://192.168.20.10/re1.html

Programming with a Local Telephone or the Unit’s Keypad

Start with Step 1 below for local programming with the unit’s keypad or a local telephone.

1.Enter “###” (unless the programming prefi x has been changed) then the Master Programming Code (123456, unless it has been changed), then “#”.

2.Use the telephone keys or keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts.

3.To disconnect after programming, enter “99#”.

NOTE: The RE-2 will automatically exit programming mode after fi ve minutes of no programming activity.

Remote Programming with a Telephone

For remote programming, the RE-2 can be called from any TouchTone® telephone. Once the connection is made, the programming keystrokes are identical to what would be entered at the unit’s keypad or from a local telephone. Refer to the next section for details of the keystrokes for each programming PPN.

Remote Telephone Connection

1.Dial the telephone number of the line that the RE-2 is connected to.

2.Let the telephone ring twice and hang up.

3.After 10 seconds, but before 30 seconds, call back to the same telephone number.

4.The RE-2 will answer and sound a tone for 2 seconds.

5.The RE-2 will wait for approximately six seconds for the caller to enter the Master Programming Code.

6.Enter password (123456, unless it has been changed), then “#”.

7.Use the telephone keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts.

8.To disconnect after programming, enter “99#”.

14

Image 16
Contents RE-2 Contents FeaturesAccess Methods System FeaturesProduct Description OperationInstallation Information Component Locations Help ButtonWiring Diagram Typical Gate Installation WiringEntry System Mounting Pedestal MountingWall Mounting Recessed MountingTelephone Wiring Telephone Wiring OptionsMultiple Unit Installations Command Prefix for Multiple UnitsGate Control Control WiringDoor or Pedestrian Gate Control POWER, BATTERY, & Ground Wiring Power WiringBackup Battery Optional Remote AntennaKeyswitch Installation Optional KeyswitchOptional Remote Keypad Camera Installation Optional Color Cctv CameraProgramming with a Computer Programming AccessSystem Requirements Setting UP a Windows XP DIAL-UP Network Connection Programming with a Local Telephone or the Unit’s Keypad Remote Programming with a TelephoneProgramming Reference Programming ControlBasic System Programming Entry Code ProgrammingTransmitter Programming Telephone ProgrammingAdvanced System Programming Press Obstacle Facility ID Press AddressPress Input Type Press CountSpeakerphone Volume System AdjustmentsDigital Speech Volume RE-2 Operation To Enter Programming Mode To Exit Programming Mode & Save ChangesRe-entering a Command After a Mistake Call Waiting Feature On/OffDimension Drawing SpecificationsTroubleshooting Programming Worksheet Time ZonesRelay # Time Zone Linear Limited Warranty Important Wireless Information