Valcom V-9908 dimensions Typical Connections Fully Supervised System

Page 5

Laptop computer

 

 

 

Remote Activation

 

 

 

 

 

 

Single Pole Switch

 

 

Valcom Amplified

 

 

 

 

 

 

RS 232

Remote Message Play Inputs

 

Supervised Speakers

CancelMessage

 

 

 

 

 

Program Port

 

 

 

 

 

Ground

Message 8

Message 7 Message 6 Message 5 Message 4 Message 3

Message 2

Message 1

 

 

 

 

 

 

Connect field wiring

 

 

 

 

 

 

directly to speaker

 

 

 

 

 

 

terminals or speaker

 

 

 

 

 

 

pigtails.

Tip

 

 

 

 

 

 

 

 

 

 

 

Tip

Ring

 

 

 

 

 

Ring

Gnd

 

 

 

 

 

-24vdc

 

 

 

 

 

Gnd

 

 

 

 

 

 

 

 

 

 

 

-24vdc

 

 

 

 

 

 

COM

 

 

 

 

 

 

- 24VDC

 

 

 

 

 

 

 

V-9999

 

 

 

 

 

 

EOL

 

 

 

 

 

9 Volt Alkaline

Terminator

 

 

 

 

 

not included

 

 

 

 

 

Battery

 

 

 

 

 

 

Figure 3: Typical Connections - Fully Supervised System

Default shorting jumper positions are shown. (from top to bottom – up, up, down).

The only time that these need to be moved is when connecting the output of the V-1096 to a lo-z microphone input. In this case, all of the jumpers must be moved. (From top to bottom - down, down, up)

When the V-9908 is not being used as shown in Figure 3, a V-1096 Audio Adapter must be utilized.

1)Connect the audio output of the V-9908 to the audio input of the V-1096.

2)Connect the audio output of the V-1096 to the audio input of the receiving system. Examples of receiving systems include a tip/ring telephone input on a Valcom Page Control, the tip/ring audio input of one or more Valcom Self Amplified Speakers, a line level music or auxiliary input on a Valcom page control, IP Audio gateway or amplifier, or a lo-z microphone input. In the case of a lo-z microphone input, such as that found on Valcom MultiPath or Class Connection systems, all of the shorting jumpers must be moved from the default positions shown above.

3)If the audio input of the receiving system requires a “loop start” connection, then connect the message play contacts of the V-9908 to the Contact Closure input of the V-1096.

4)If the audio input of the receiving system requires an activation closure, then connect the message play contacts of the V-9908 to the activation input of the receiving system.

5

947980

Image 5
Contents Dimensions FeaturesSpecifications IntroductionIndicators Figure InstallationSystem Fault Monitoring System OperationValcom, Inc Repair and Return Dept Hollins Road Roanoke, VA System TroubleshootingProgramming the Message Panel Contact Closure Inputs Serial Programming Input9 V Alkaline BatteryTypical Connections Fully Supervised System Preprogrammed Messages included