Telex US2002 manual PA Output, Speaker Output, Expansion Input /Output

Page 35

Intercom Channels, Balanced Mode (SW2 set to BAL position) Output Level: 1 Vrms nominal

Input Impedance: 300 ohms

Bridging Impedance: greater than 10,000 ohms

Sidetone: -40 dB, 35 dB adjustable range Call Signaling:

Send: 20 kHz ±100 Hz, 0.5 Vrms ±10%

Receive: 20 kHz ±800 Hz, 100 mVrms Mic-Kill Frequency:

Send: 24 kHz ±300 Hz, 0.5 Vrms ±10%

Detect: 24 kHz ±800 Hz, 100 mVrms Noise Contribution: less than -70 dB

Common Mode Rejection Ratio: greater than 50 dB

Connector Type: One XLR-3M and XLR-3F pair, wired in parallel, for each channel Pin 1 Common

Pin 2 Intercom audio low and +24 VDC input Pin 3 Intercom audio high and +24 VDC input

Intercom Channel, Unbalanced Mode (SW2 set to UNBAL position) Output Level: 1 Vrms ±10%

Input Impedance: 150 ohms

Bridging Impedance: greater than 10,000 ohms Call Signaling:

Send: 11 ±3 VDC

Receive: 4 VDC minimum

Connector Type: One XLR-3M and XLR-3F pair, wired in parallel, for each channel Pin 1 Common

Pin 2 +24 VDC input

Pin 3 Intercom audio high

PA Output

Output Level: 235 mVrms nominal

Connector Type: 1/8-inch Stereo Phone Jack

Tip: PA output high

Ring: Not used

Sleeve: Common

Speaker Output

Output Level: 0 dB nominal (1.0 Vrms)

Output Impedance: 1000 ohms nominal

Frequency Response: 200 Hz to 8 kHz +1/-3dB

Connector Type: RCA Phono Jack

Tip: Speaker output high

Sleeve: Common

Expansion Input /Output

Type: 2.0 mm stereo phone jack

Tip: Talk output

Ring: Listen input

Sleeve: Common

Intercom User Station US2002 - 35

Image 35 Contents
Telex Page FCC Statement Table of Contents Index of Figures Introduction US2002 Reference View See numbered features, Features Unpacking Configuration Pre-checkConfiguration Switch Settings Headset Microphone Type Selection DIP Switch For binaural operation with 2 speakers Jumper Description Setting for JumpersCentral Master Station vs Remote Station Mounting ConfigurationsExternal Program Input and PA Output Intercom User Station US2002 Intercom User Station US2002 Intercom User Station US2002 Intercom User Station US2002 Intercom User Station US2002 Intercom User Station US2002 US2002 Headset Station Configuration with 2 Power Supplies Typical Remote Headset Station Typical Remote Monaural Speaker Station Typical Remote Binaural Speaker Station An example of all locally powered US2002 intercom stations External Audio Input and PA Output Audiocom Intercom Cables Intercom User Station US2002 Power-Up Check Intercom User Station US2002 US2002 Bottom View Receiving Calls Normal vs Programming ModeVolume Adjustment Microphone Mute During Talk Using Mic Kill Program Input GeneralDynamic-mic Headset Panel Microphone or Electret-mic HeadsetExpansion Input /Output PA OutputSpeaker Output Panel Microphone Amplifier External PowerHeadphone Amplifier Factory Service and Parts Information Page Quick Reference 9350-7748-000 Rev. A, 1/2003