Polycom DOC2548A manual Rtm Isdn/Rtm

Page 36

Chapter 1- Hardware Description

Table 1-9RMX™ 4000 Slot Numbering

Slot ID/No.

Card/Component

Requirement

 

 

 

12

Fan Drawer

Mandatory

 

 

 

13-16

RTM ISDN/RTM

Either an RTM ISDN or an RTM LAN

 

LAN

card is mandatory in combination with a

 

 

Media card. The RTM ISDN/RTM LAN

 

 

board must be inserted in a slot opposite

 

 

any MPM+ card.

 

 

 

17

RTM-IP 4000

Mandatory

 

 

 

18

Blank Panel

Not Available (NA)

 

 

 

19-21

Power Modules

Mandatory:

 

 

With AC power, 3 power supplies are

 

 

installed, with the 3rd redundant.

 

 

With DC power, 2 power supplies are

 

 

installed with the 2nd redundant. The

 

 

center slot (#20) on the rear of the RMX

 

 

4000 is disabled and is fitted with blank

 

 

panel.

 

 

Note: Protective bonding conductor size

 

 

is 14AWG (1.5mm) within the Power

 

 

Entry Model.

 

 

 

1-30

Image 36
Contents Polycom RMX 4000 Hardware Guide USA Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ Regulatory Notices Russian Communication CertificateTable of Contents Component Replacement Hardware Description Power Supply Power ConsumptionPhysical IP ProtocolsSystem Capacities Following table summarizes the different system capacitiesSystem Functions Capacity MPM+ Resource Capacities Card Resources TypeHD720p HD1080p @30fps @60fps MPM+ Resource Type Maximum Capacity 4 MPM+ Cards CIFSafety Requirements Site Safety RequirementsGeneral Installation Precautions Rack Mount Safety PrecautionsInstalling the RMX Unpacking the RMXPolycom RMX 4000 Hardware Guide Installing the RMX in a Rack or as a Standalone Standalone RMX 4000 InstallationRack Mount Preparations 2Installing chassis runners and RMX in a rack Placing the RMX 4000 in a 19 Rack3RMX 4000 Rack Mount Placing the RMX 4000 in a 23 Rack 4Removing and attaching 19 and 23 bracketsReverse Mounting the RMX 4000 in a Rack To reverse mount the RMX 4000 on a 19 rackConnecting the RMX 4000 to Power Sources Connecting the RMX 4000 to AC Power Make sure that the power button is switched OFF on the RMXConnecting the RMX 4000 to -48DC Selv Power Types of DC Circuit Breakers installed on the RMX Type a Type BConnecting Cables on the RMX To connect the cables AC and DC systems RTM-IPFirst-time Power-up For more information about specific card connections, seeRTM LAN on RMX 4000 Components RMX 4000 Front PanelShows the front panel of an RMX 4000 DC system Component Description RMX 4000 Rear Panel 9RMX 4000 AC Rear ViewRTM-IP 10RMX 4000 DC Rear ViewFollowing items appear on the RMX 4000 rear panel LAN 3 CntlRTM Isdn Standby button Toggle between CPU activation and standbyAC Power Entry Module PEM ISDN/PSTN Clock SourceDC Power Rail Module Component Slot AllocationSlot ID/No Card/Component Requirement RTM ISDN/RTM RMX 4000 Front Panel LEDs Following items appear on the RMX 4000 front panelComponent LED Color DescriptionCard removal Initiated The card Card Insertion Initiated If duringCntl 4000 Unit RMX 4000 Rear Panel LEDs RTM-IPFollowing LEDs appear on the RTM-IP 4000 card LED Color Description NameFollowing LEDs appear on the RTM LAN Function NameRTM Isdn Following LEDs appear on the RTM IsdnComponent Replacement Component Replacement Using the Modified PMC Compatible Ejector Lever HandleReplacing the Cntl 4000 Module Replacing an AC Power Supply Module Replacing an AC Power Entry Module PEM Replacing a DC Power Rail Module PRM Component Replacement Replacing the Fan Drawer Carefully slide the Fan drawer out through the front panelInserting an Air Filter Optional in the Fan Drawer Replacing a Faulty MPM+ Card Removing the MPM+ Card from the MCUComponent Replacement Installing the Replacement MPM+ Card Carefully slide the MPM+ card out through the front panelInstalling a New MPM+ Card in a Powered On RMX Replacing a RTM Isdn CardPRI Cables Replacing the RTM-IP Replacing the RTM LAN Replacing the Fabric Switch Module FSM