Aiphone JB-2MED operation manual Wiring English

Page 6

Wiring

English

Securely insert wires into each terminal as shown.

1.Master monitor station JB-2MD or JB-2MED

2.Sub monitor station JB-2HD or sub station JA-2SD

3.Video entrance station

4.Video or audio entrance station

5.Power supply +, - (DC 18 V)

6.Optional door release EL-9S (AC 12 V, 0.35 A) or equivalent, requires a separate AC transformer. Run separate cables for the audio/video and door release. Door release contact: AC/DC 24 V, 0.5 A (dry closure contact L, L).

7.Optional call extension speaker IER-2

8.Impedance matching switch

Terminate farthest sub station by putting SW in ON position. Otherwise both video and audio may become distorted.

9.Optional selective door release adaptor RY-3DL Use RY- 3DL when connecting a door release for 2 locations.

10 Sensor (locally available)

.Use outer equipment (sensor, etc) with dry-closure contacts.

For details, please contact your local distributor.

JB-2MED only.

NP: Non-polarized

- 6 -

Image 6
Contents JB-2MED, JB-2MD, JB-2HD Package Contents InstallationWiring distance Installation locations EnglishWiring Cable EnglishMounting Mounting EnglishOptions English Wiring Diagram JA-2SDWiring English Bright Setting UPNames NamesSetting up English Answering a door call Voice actuate mode EnglishOperations Activating door release English Answering a door call Manual mode EnglishInstant voice call function English Entrance monitoring EnglishAutomatic recording Room-to-room communication EnglishTransfer entrance call English Manual recordingPress the Play button to view the newest picture Absence set Auto absence recording EnglishPlay Automatic updating function for recorded screens EnglishSub screen enlargement 16-picture/4-frame mode only English Save EnglishSurveillance Setting Technical PrecautionsSpecifications WARRANTYEnglish