Aiphone JB-2MED operation manual Mounting English, Options English

Page 4

 

 

 

 

3-2

 

3

 

MOUNTING

 

 

 

 

 

 

 

 

3-1

JB-2MED

MONITOR

TALK

JB-2MD

JB

JB-2HD

-2MD

 

TALK

#1

[1] [2] [3]

83,5 mm (3-5/16")

 

(PR)

E

[1]

SW

(BL)

 

P(GR)

b2

(YE)

 

b1

[3]

(OG)

V -

 

V +

(RD)

[4]

 

 

(BR)

 

 

JB-2M(E)D

[2]

JB-2HD

#2 #1

#1

#2

L

(BR)

[5]

L

(RD)

c1

(OG)

[6]

(YE)

c2

 

1

2

9mm (3/8")

PR: Purple

PR: Violet

PR: Lila

PR: Violeta

PR: Paars

BL: Blue

BL: Bleu

BL: Blau

BL: Azul

BL: Blauw

GR: Green

GR: Vert

GR: Grün

GR: Verde

GR: Groen

YE: Yellow

YE: Jaune

YE: Gelb

YE: Amarillo

YE: Geel

OR: Orange

OR: Orange

OR: Orange

OR: Naranjo

OR: Oranje

RD: Red

RD: Rouge

RD: Rot

RD: Rojo

RD: Rood

BR: Brown

BR: Brun

BR: Braun

BR: Marrón

BR: Bruin

PS-1820

 

PS-1820DIN

PS-1820S

 

PS-1810DIN

PS-1820UL

 

 

[2]

[3]

[4]

 

 

 

83,5 mm

 

 

(3-5/16")

 

Mounting

English

[1]Screws (x2)

[2]Mounting bracket

[3]1-gang box

[4]Din rail

1.Press the RELEASE button (to insert or remove the wire).

2.Insert the cable into the terminal.

NOTES: When a 1-gang box is not installed, the cable can be surface-run to the top or bottom of the unit. Cut the cable inlet to allow passage of the wiring into the unit.

Options

English

[1]Foot switch

Connect a locally available pedal foot switch to PURPLE and BLUE wires (dry closure contact).

[2]Manual Press-to-Talk restriction

Short PURPLE and GREEN wires together to prevent manual TALK button operation.

[3]Selective door release

Please refer to the wiring diagram #9 for detail connection.

[4]Video output to video monitor, video switcher, etc. (NTSC,1 Vp-p/75Ω)

[5]Single door release

Connect BROWN and RED wires from connector #2 to a single door release (or to the RY-3DL as shown on the wiring diagram).

[6]Sensor (JB-2MED only)

NOTES: 1. For JB-2HD, only functions [1] and [2] are available.

2.Cut off unused wires and insulate the ends to prevent shorting.

3.Provide a box deep enough to accommodate all cables including options.

- 4 -

Image 4
Contents JB-2MED, JB-2MD, JB-2HD Package Contents InstallationInstallation locations English WiringWiring distance Cable EnglishMounting English MountingOptions English Wiring Diagram JA-2SDWiring English Setting UP NamesBright NamesAnswering a door call Voice actuate mode English Setting up EnglishOperations Answering a door call Manual mode English Instant voice call function EnglishActivating door release English Entrance monitoring EnglishRoom-to-room communication English Transfer entrance call EnglishAutomatic recording Manual recordingAbsence set Auto absence recording English PlayPress the Play button to view the newest picture Automatic updating function for recorded screens EnglishSub screen enlargement 16-picture/4-frame mode only English Save EnglishTechnical Precautions Surveillance SettingSpecifications WARRANTYEnglish