Aiphone JK-DVF-AC operation manual Default 10 Sec Default 3 Sec

Page 10

 

 

(orange) (green)

Input the master code twice.

 

Illumination Blinking

(Default :

)

Bleep, Bleep

Français English

Setting the key illumination time

Setting the relay output time

(Default: 10 Sec.)

(Default: 3 Sec.)

 

When setting relay 1 When setting relay 2

Reset Settings

External output setting

(Default: OFF)

 

Nederlands

Input the setting code.

Input the setting code.

Input the setting code.

Illumination Blinking

Illumination

Blinking

Bleep

 

Bleep

Input the setting code.

Illumination Blinking

Bleep

Input the setting code.

Illumination Blinking

Bleep

During

During forced

During lockout

OFF

and forced

Lockout

entry output

entry output

 

Inputting of illumination time

Inputting of relay output time

 

 

(ex.: 20 seconds)

(ex.: 99 seconds)

 

 

10 - 99

01 - 99

 

 

Indicator is lit up at all times: 00

Latched () : 00

 

 

Illumination Blinking

Illumination Blinking

Illumination Blinks three times

Illumination Blinking

Bleep, Bleep, Beep

Beep

Beep

Beep

 

 

- When the

 

key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.

Indicator

Blinking

 

 

goes out

(If the

 

key is included in the user code and the master code, the system does not exit the setting mode.)

 

 

 

 

 

 

 

 

 

 

 

Bleep,

- You can continue the setting up operation by entering an arbitrary setting code.

 

 

 

 

 

Bleep

 

 

 

 

 

 

 

 

 

 

 

 

·() If the latched status has been set and the door is unlocked, it will not be locked again until the user code is entered (or the request to exit/entry button is pressed, or

the key is pressed while timer-linked unlocking is set).

·When the door is unlocked during relay outputting (including when latched), the system cannot be switched to the setting mode.

·If the power is turned off and

the , , and keys are pressed simultaneously while the unlock 1 input status is active (short circuit between terminals PB1 and C), the settings can be returned to their default values by turning the power back on and

pressing the , , and keys simultaneously for 3 seconds.

·When setting the external output, do not set the relay 2 output to be latched.

9

Image 10
Contents JK-DVF-AC AAN UIT OFFGroup 1 / groupe 1 / groep Group 2 / groupe 2 / groep Precautions ContentsMounting Package ContentsMounting locations Part Names MountingOutline of connections and wiring distance Wiring and ConnectionsTerminal names Connection examples Connection of Relay 1 onlyFUNCTIONS/SETTING UP for Access Control English Français Nederlands Default 10 Sec Default 3 Sec Lockout Default OFF Auto-relock Anti-tailgate Timer-linked unlocking Operation of Access ControlTechnical Precautions Unlocking using the request to exit/entry buttonAccess control keypad SpecificationsWarranty General