Aiphone JK-DVF-AC operation manual Part Names, Mounting

Page 5

Mounting

1.Detach the door station from the flush mount back box by removing the screws with the special screwdriver that is supplied with the unit.

2.Attach the flush mount back box to the wall.

3.Route wiring through the flush mount back box and connect wires to the door station.

*See page 5 and 6 for details on wiring and connections.

4.Attach the door station to the flush mount back box.

*Be sure to use the original screws to reattach the door station to the flush mount back box.

English Français

114 mm (4-1/2")

Flush mount back box

Using the transparent nameplates

Inserting the transparent nameplates

1 Remove the door station from the flush mount back box. 2 Peel off the protective seals on the plate (both sides).

3 Fill in the name of the resident on the transparent nameplate.

Nederlands

Door station

Transparent nameplate

Special

Loosen

screwdriver

 

 

Tighten

263 mm

(10-3/8")

45 mm (1-3/4")

Special screws (4 pcs)

Be sure to leave 25 mm (1") of white space on the left end to account for insertion.

4 Insert the filled-in transparent nameplate at the specified insertion opening on the rear side of the door station (indicated

with in diagram).

25 mm

(1")

ABC

To

insertion

opening

Wall

Notes on handling wires

After stripping back the cable jacket from the conductors, waterproof the area that has been cut by wrapping insulation tape around the end of the jacket. Additionally, position

the cable downward to prevent rainwater or moisture from seeping into the cable.

Do not bend the wires at a sharp angle to prevent them from breaking as they age.

Areas where the cable jacket was removed

Do not bend at a sharp angle.

Flush mount back box

PART NAMES

Video door station

Access control keypad

Special screws for panel mounting

Camera

Microphone

White light LED

Speaker

Directory card

Call button

LED indicator (Orange)

LED indicator (Green)

Keys (Yellow)

Special screws for panel mounting

4

Image 5
Contents JK-DVF-AC Group 1 / groupe 1 / groep Group 2 / groupe 2 / groep OFFAAN UIT Contents PrecautionsMounting locations Package ContentsMounting Mounting Part NamesTerminal names Wiring and ConnectionsOutline of connections and wiring distance Connection of Relay 1 only Connection examplesFUNCTIONS/SETTING UP for Access Control English Français Nederlands Default 10 Sec Default 3 Sec Lockout Default OFF Auto-relock Anti-tailgate Technical Precautions Operation of Access ControlTimer-linked unlocking Unlocking using the request to exit/entry buttonWarranty SpecificationsAccess control keypad General