FUNCTIONS/SETTING UP FOR ACCESS CONTROL
This section explains the settings of each function, including the master code for management, the user code for unlocking, the buzzer and the LEDs.
About the setting mode:
Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for the desired function. After settings have been made, enter the following setting codes to continue the setting operation. Press to exit the setting mode.
| Setting items |
| Allowable setting range | Default value | Setting code | |
Setting the code length |
|
| 4, 5, or 6 digits | 4 digits |
| |
Change the length of the master code and the user code. |
|
|
|
| ||
)They both must be the same length. |
|
|
|
|
| |
Setting the master code |
|
| 1 | 1234 |
| |
Enter a master code using between 4 and 6 digits (alpha or numeric) to | Valid keys: 0 - 9, A, B |
|
| |||
switch to the setting mode. |
|
|
|
|
| |
) The number of digits in the code can be set by setting the code length. |
|
|
| |||
Setting the code for user group 1 |
| Number of codes: 60 | - | - | ||
Set the unlocking code for user group 1. |
|
| Valid keys: 0 - 9, A, B |
|
| |
) The number of digits in the code can be set by setting the code length. |
|
|
| |||
Setting the code for user group 2 |
| Number of codes: 40 | - | - | ||
Set the unlocking code for user group 2. |
|
| Valid keys: 0 - 9, A, B |
|
| |
) The number of digits in the code can be set by setting the code length. |
|
|
| |||
Setting the key illumination time |
|
| Illumination time: 10 to 99 | 10 Sec. |
| |
Set the length of time that the keys will be lit up after they are pressed. | seconds, or continually lit |
|
| |||
Setting the relay 1 output time |
|
| Output time: 1 to 99 | 3 Sec. |
| |
Set the output time of relay 1. |
|
| seconds, or latched |
|
| |
Setting the relay 2 output time |
|
| Output time: 1 to 99 | 3 Sec. |
| |
Set the output time of relay 2. |
|
| seconds, or latched |
|
| |
Reset Settings |
|
|
| - | - |
|
Return all the settings to their default values. |
|
|
|
| ||
External output setting |
|
| · OFF | OFF |
| |
The alarm or security system connected to the terminal of relay 2 will be | · During Lockout |
|
| |||
activated when the "Lockout" * or the forced entry* is carried out. | · During forced entry output |
|
| |||
* "Lockout": Refer to VIII below. *Forced entry: This function is linked with | · During lockout and forced |
|
| |||
the door open/close sensor (N.C.) which is connected to PB2 and C, and | entry output |
|
| |||
carried out when opening the door without activating this unit. (For example, |
|
| ||||
entry in an improper manner, manual unlock, etc.) |
|
|
|
| ||
) If there is a way to open the door without activating this unit, such as |
|
|
| |||
manual unlock, do not make the external output setting for the forced entry. |
|
|
| |||
Lockout |
|
|
| ON/OFF | OFF |
|
If several incorrect access codes are attempted, the code input function is | Invalid number of times: |
|
| |||
disabled for a programmed period of time. |
| 10 to 99 times |
|
| ||
· When "Lockout" is activated, the LED (Orange) indicator and the keypad | Invalid time: |
|
| |||
blink, and the buzzer sounds for 3 seconds. This is just a sound to inform | 10 to 99 seconds |
|
| |||
you that the function has been activated. It is not a warning sound. If you |
|
| ||||
want a warning to be sounded, please use the external output function to |
|
|
| |||
activate a |
|
|
|
| ||
· The unlock function will work when the request to exit/entry button is |
|
|
| |||
pushed, even while the "Lockout" function is operating. |
|
|
|
| ||
|
|
| ON/OFF | OFF |
| |
After the door has been linked to the door open/close sensor (N/C), and |
|
|
| |||
unlocked, it will relock itself one second after being closed, thus preventing |
|
|
| |||
the entry of an unauthorized third party. | 1 |
|
|
|
| |
|
|
| Linked relay: relay 1 | Linked relay: relay 1 |
| |
The system can be set to unlock the door by pressing the | key within | relay 2 | 0 key illumination: OFF |
| ||
the set time and linking it to the external timer (N/O). The operations for the | relay 1 and 2 |
| ||||
LEDs and the buzzer after unlocking are the same as those used to perform | 0 key illumination: ON/OFF |
|
| |||
user code unlocking. When the door is linked to the timer, unlocking can be |
|
| ||||
performed using the user code and the request to exit/entry button. When |
|
|
| |||
latch output is performed for the relay settings, the relay turns ON/OFF |
|
|
| |||
every time the | key is pressed. |
|
|
|
|
|
|
|
|
|
|
| |
Operation tone settings |
|
| ON/OFF | ON |
| |
Set the tone heard when the keypad is being used to ON/OFF. |
|
|
|
•The setting can be saved even when the power is off.
•The system cannot be switched to the setting mode while the relay is unlocked.
•When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system will exit the setting mode. (If a key is pressed during that time, the timer will start over.)
•Neither the request to exit/entry button nor the
•The volume (the check tone, operation tone, etc.) from the door station may become lower according to the mounting status.
1 : When the
7only possible when user code unlocking is performed.