BUILDING YOUR SYSTEM WITH MULTIPLE VOR-

be mixed with the other inputs to create Outputs 1-8, A-D, Ref 1, Ref 2, and W, X, Y, and Z bus outputs.

Submatrix

Bus W WB0 WB1 WB2 WB3 WB4 WB5 WB6 WB7

Bus X XB0 XB1 XB2 XB3 XB4 XB5 XB6 XB7

Bus Y

YB0 YB1 YB2 YB3 YB4 YB5 YB6 YB7

Bus Z ZB0 ZB1 ZB2 ZB3 ZB4 ZB5 ZB6 ZB7

Figure 1. W, X, Y, and Z submatrices.

EF Bus Reference. In a system with multiple devices, if all devices need the same echo canceller reference, one device should be designated to put its echo cancel- ler reference (either Ref 1 or Ref 2) on the EF bus to be used as the EF Bus Reference.

All other Vortexes may use the EF bus reference as the reference for their echo can- cellers, or they can use their own internal references. The references may include a mix of any input, with crosspoint gains, including W, X, Y, and Z busses.

NOM Bus. All busses on the EF Bus contain NOM information. See “NOM Active” on page 29 of the Vortex Reference Manual for more information on how NOM attenuation is applied.

Note. The EF Bus must be connected so that the EF BUS OUT of one Vortex device is connected to the EF BUS IN of another Vortex. Connecting EF BUS IN to another EF BUS IN (or EF BUS OUT to EF BUS OUT) will not work. See“Connector Pinouts” on page 43 for pinout of Cat 5 cable.

4.CONFIGURE YOUR ECHO CANCELLER REFERENCE

Review what inputs need to be included in your echo canceller reference — See “Build Your Echo Canceller Reference (if not using Preset 0)” on page 13. of the Vor- tex Reference Manual. Remember that each microphone needs an echo canceller ref- erence. If all microphones are in the same room and use the same reference, configure the echo canceller reference on one Vortex and assign it to the EF Bus as the EF Bus Reference. Only one Vortex out of multiple units linked together can put

Vortex® Applications and Presets Guide

4

Technical Support: (800) 932-2774

Image 6
Contents Vortex EF2280 Applications and Presets Guide VORTEXAPPGUIDE-0100-01 Presets Introduction Assign Outputs Configure the SubmatrixAssign Inputs EF BusConfigure Your Echo Canceller Reference Automixer Settings for Multiple Vortexes Operating as an Independent AutomixerAM1 Connecting Multiple Vortexes Terminating the VortexEF Bus Terminator Cat-5 cable Connecting the Vortex with Other EchoFree Devices Vortex Factory Preset 0 Default Left Program Audio Right Program Out Vortex Factory Preset 2 Split, Mono Vortex Factory Preset 4 8 mics/Zone Presets Stereo Recorder Presets Vortex Factory Preset 6 4 mics/Zone Presets 3 Reserved Preset