Cooper Lighting GT Series Attaching access cover and lens, Installing the light shield

Page 4

4.Connect white fixture wire to white supply wire (neutral). Secure with wire nut (not provided).

5.Be careful to connect the wires correctly. Make sure no bare strands of wire extend from the wire nut or other approved wire connectors (not supplied).

Attaching access cover and lens

1. Attach the access cover to the light fixture using screws provid-

ed. Access cover should be positioned as shown in P. NOTE: Make sure all wiring is inside of the fixture arm before the access cover is secured.

2.To attach the optical assembly to the housing, first insert the three lens assembly mounting screws into the three holes

P

ENGLISH

inside the fixture. Do not fully tighten the screws at this point.

Q

Position the optical assembly over the fixture with slotted holes

 

over the mounting screws (Q). Carefully seat the optical assem-

 

bly over the mounting screws and rotate the optical assembly

 

clockwise until it stops. Tighten all screws.

 

Installing the light shield

Before installing the lamp, position the light shield over the lamp socket and press firmly into position (R). The shield is friction fitted around the socket. The end of the light shield should be seated in

R

the lip of the lens. You can rotate the light shield in any direction to block the light from the fixture. NOTE: Do not attempt to adjust or touch the light shield while the lamp is on as the light shield gets very hot. If the lamp has been on, allow the light shield time to cool before touching.

Installing the lamp

1.Screw the bulb securely into socket.

2.Back the bulb out one or two turns, then screw bulb back to insure proper position in socket.

Installing the wire grill guard

1.First, locate the two wire tabs on the wire grill. Insert these two tabs in the bottom of the lens.

2. Press the other end of the grill guard in position, and the wire clip

S

will lock the grill guard in place (S).

 

3.To remove the grill guard squeeze the wire clip and gently pull the guard out.

Installing the light sensor

1.Make sure the screw in the center of the receptacle (on top of the fixture) is tight.

2.Match up the largest prong on the sensor to the largest slot in the receptacle.

3.Push the sensor down into the receptacle and twist clockwise 1/4 of a turn to lock in place.

4.Turn on the main power at the main fuse/breaker box. NOTE: When the power is initially turned on, the light may come on, even during daylight. However, the light will turn off after two or three minutes and will only come on

4

Image 4
Contents English Español How it works What you needWhat’s included What to knowWiring your fixture Putting up your fixtureAttaching access cover and lens Installing the light shieldInstalling the lamp Installing the wire grill guardOperating your fixture Installing the adjustable photo control coverWhat to do if Two year limited warranty Cómo funciona Qué se necesitaQué se incluye Qué necesita saberInstalación del portalámparas Cableado del portalámparasConexión de la cubierta de acceso y del lente Instalación de la protección de la luz Instalación del focoInstalación de la protección de rejilla de alambre Instalación del sensor de luzOperación de su portalámparas Qué hacer siGarantía Limitada por dos años

GT Series specifications

Cooper Lighting, a leader in innovative lighting solutions, has made significant strides in the quest for energy efficiency and versatility with its GT Series. This line of fixtures has been designed to provide superior illumination while meeting the evolving needs of various commercial and industrial environments.

The GT Series is characterized by its robust construction and sleek design, which allows it to fit seamlessly into a variety of settings, from warehouses to retail spaces. One of its main features is the integration of LED technology, which not only reduces energy consumption but also enhances lighting quality. LED fixtures tend to have a longer lifespan compared to traditional lighting solutions, which translates to lower maintenance costs and less frequent replacements.

One of the standout technologies employed in the GT Series is the use of advanced optics. The fixtures are designed with precision-engineered optics that maximize light distribution and minimize glare, ensuring that spaces are illuminated evenly and effectively. This feature is particularly beneficial in settings where visual clarity is paramount, such as manufacturing floors and assembly lines.

Another significant characteristic of the GT Series is its adaptability. The fixtures come equipped with a range of lumen output options and various distribution patterns, allowing users to customize their lighting based on specific application needs. This flexibility makes the GT Series a versatile choice for a multitude of lighting scenarios, ensuring optimal performance regardless of the environment.

Moreover, the GT Series includes smart technology capabilities, enabling connectivity and integration with building management systems. This feature allows for automated controls, such as dimming and scheduling, to further enhance energy savings and improve overall efficiency.

In addition to its performance-related features, the GT Series is designed with sustainability in mind. By utilizing recyclable materials and reducing energy consumption, these fixtures support green building initiatives and contribute to a reduced carbon footprint.

Overall, the Cooper Lighting GT Series represents a forward-thinking approach to commercial lighting. With its combination of advanced technologies, customizable options, and energy-efficient design, this product line not only meets the demands of contemporary lighting applications but also sets a new standard for quality and performance in the industry. Investing in the GT Series ensures that spaces are not only well-lit but also equipped to meet future challenges in an ever-evolving landscape.