KX-TC2000NZB / KX-TC2000N ZW / KX-TC2000NZF
12.2. How to change the channel
12.3. Adjustment
| Adjustment Items | Test Mode | Adjustment | Procedure | Check or |
|
|
| Point |
| Replace |
|
|
|
|
| Parts |
(A) | Battery Low | 3ch Talk | - | 1. Adjust the power supply voltage to DC3.60V,and confirm so that the | IC1 |
| Confirmation |
|
| reading of oscillosope is High. |
|
|
|
|
| 2. Adjust that power supply voltage to DC 3.40V, and confirm so that the |
|
|
|
|
| reading of oscilloscope is Low. |
|
(B) | TX VCO | 3ch Talk | T6 | 1. Adjust T6 so that the reading of the Digital Voltmeter is 1.5V ± 0.3V. | IC1, X1, |
| Adjustment |
|
|
| T6, DV1 |
(C) | RX VCO | 3ch Talk | - | 1. Confirm so that the reading of the Digital Voltmeter is 0.7 ~ 3.0V. | IC1, X1, |
| Confirmation |
|
|
| L6, C24 |
(D) | TX Frequency | 3ch Talk | VC1 | ∙ Adjust VC1 so that the reading of the frequency counter is 39.8750MHz | IC1, |
| Adjustment |
|
| ± 100Hz. | DPX1, T5 |
(E) | TX Power | 3ch Talk | - | ∙ Confirm so that the reading of the RF VTVM is more than | IC1,Q3,Q4, |
| Confirmation |
|
| (50Ω load). | Q5, DPX1 |
(F) | RX Sensitivity | 3ch Talk | T3 | 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev. | DPX1, |
| Confirmation |
|
| 0KHz). | T3,IC1, |
| (2nd IF output) |
|
| 2. Confirm that the reading of RF VTVM is the maximum value (more than | CF1, CF2 |
|
|
|
|
| |
|
|
|
| 15mV). |
|
(G) | Noise Squelch | 3ch Talk | - | 1. Measure the SSG output level when the noise squelch changes from | IC1, DPX1 |
| Confirmation |
|
| Low to High. (modulation frequency 1KHz, dev.3kHz) |
|
|
|
|
| 2. Confirm that the SSG output level is |
|
(H) | Speaker | 3ch Talk | - | 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev. | IC1 |
| Output Level |
|
| 3KHz). |
|
| Confirmation |
|
| 2. Confirm that the reading of AF VTVM is more than 30mV. |
|
|
|
|
|
| |
|
|
|
| (distortion: less than 5%) (volume High). |
|
(I) | Mic Modulation | 3ch Talk | - | 1. Apply a MIC signal (1KHz, 5.0mV at 600Ω load). | IC1, DV1 |
| Factor |
|
| 2. Confirmation so that the reading of FM Deviation Meter is 3.4KHz ± |
|
| Confirmation |
|
|
| |
|
|
| 0.4KHz. |
| |
|
|
|
|
| |
(J) | Data | 3ch Talk | - | ∙ Confirm for 5.0 ± 1.0KHz FM Deviation Meter reading. |
|
| Modulation |
|
|
|
|
| Confirmation |
|
|
|
|
(K) | Battery low | - | - | 1. Apply 3.50V between BATT(+) and | IC1 |
| Confirmation |
|
| 2. Confirm that there is no flashing of RECHARGE LED. |
|
|
|
|
|
| |
|
|
|
| 3. Apply 3.40V between BATT(+) and |
|
|
|
|
| 4. Confirm that there is flashing of RECHARGE LED. |
|
The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.30).
SSG Frequency: 30.175 MHz
29