Grandstream Networks HT702, HT704, HT701 user manual Vad

Page 28

 

 

 

Subscribe for MWI

 

 

 

Default is No. When set to “Yes” a SUBSCRIBE for Message Waiting Indication will be

 

 

 

 

 

 

 

 

 

 

 

sent periodically.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Anonymous

 

 

 

Default is No. If this parameter is set to “Yes”, the “From” header along with Privacy

 

 

 

 

 

 

 

 

 

and P_ Asserted_Identity headers in outgoing INVITE message will be set to

 

 

 

 

 

 

 

 

 

anonymous, blocking Caller ID.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anonymous Call

 

 

 

Default is No. If set to Yes, incoming calls with anonymous Caller ID will be rejected

 

 

 

 

 

Rejection

 

 

 

with 486 Busy message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Special Feature

 

 

 

Default is Standard. Choose the selection to meet some special requirements from

 

 

 

 

 

 

 

 

 

 

 

Softswitch vendors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Session Expiration

 

 

 

Grandstream implemented SIP Session Timer. The session timer extension enables

 

 

 

 

 

 

 

 

 

SIP sessions to be periodically “refreshed” via a SIP request (UPDATE, or re-INVITE.

 

 

 

 

 

 

 

 

 

Once the session interval expires, if there is no refresh via a UPDATE or re-INVITE

 

 

 

 

 

 

 

 

 

 

 

message, the session will be terminated. Session Expiration is the time (in seconds) at

 

 

 

 

 

 

 

 

 

 

 

which the session is considered timed out, if no successful session refresh transaction

 

 

 

 

 

 

 

 

 

 

 

occurs beforehand. The default value is 180 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min-SE

 

 

 

The minimum session expiration (in seconds). The default value is 90 seconds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caller Request Timer

 

 

 

Default is No. If selecting “Yes” the phone will use session timer when it makes

 

 

 

 

 

 

 

 

 

 

 

outbound calls if remote party supports session timer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Callee Request Timer

 

 

 

Default is No. If selecting “Yes” the phone will use session timer when it receives

 

 

 

 

 

 

 

 

 

inbound calls with session timer request.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force Timer

 

 

 

Default is No. If selecting “Yes” the phone will use session timer even if the remote

 

 

 

 

 

 

 

 

 

party does not support this feature. Selecting “No” will allow the phone to enable

 

 

 

 

 

 

 

 

 

session timer only when the remote party support this feature. To turn off Session

 

 

 

 

 

 

 

 

 

 

 

Timer, select “No” for Caller Request Timer, Callee Request Timer, and Force Timer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UAC Specify Refresher

 

 

 

Default is Omit. As a Caller, select UAC to use the phone as the refresher, or UAS to

 

 

 

 

 

 

 

 

 

use the Callee or proxy server as the refresher.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UAS Specify Refresher

 

 

 

Default is UAC. As a Callee, select UAC to use caller or proxy server as the refresher,

 

 

 

 

 

 

 

 

 

or UAS to use the phone as the refresher.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force INVITE

 

 

 

Session Timer can be refreshed using INVITE method or UPDATE method. Select

 

 

 

 

 

 

 

 

 

“Yes” to use INVITE method to refresh the session timer. Default is No,

 

 

 

 

 

 

 

 

 

 

 

 

Send Re-INVITE After

 

 

 

Default is No, If set to “Yes”, device will send an INVITE with audio vocoders upon

 

 

 

 

 

 

 

Fax

 

 

 

completion of Fax to continue session in audio only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Silence

 

 

 

For fax machines that do not send a Disconnect when fax is done. This option

 

 

 

 

 

Detection for Fax

 

 

 

Enables/Disables the detection of silence in order to know the fax has finished. The

 

 

 

 

 

Disconnect

 

 

 

silence period is non-configurable and fixed to 7 seconds. Default is No,

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable 100rel

 

 

 

Default is No, If set to Yes, Enables the use of PRACK (Provisional Acknowledgment)

 

 

 

 

 

 

 

 

 

method.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use First Matching

 

 

 

Default is No. If set to “Yes”, device will include only the first match vocoder in its

 

 

 

 

 

 

 

Vocoder in 200OK SDP

 

 

 

200OK response, otherwise it will include all match vocoders in same order received in

 

 

 

 

 

 

 

 

 

INVITE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preferred Vocoder

 

 

 

The HT70X supports up to 5 different Vocoder types including G.711 A-/U-law, G.726-

 

 

 

 

 

 

 

 

 

32, G.723.1, G.729A/B/E, iLBC. The user can configure Vocoders in a preference list

 

 

 

 

 

 

 

 

 

that will be included with the same preference order in SDP message. The first

 

 

 

 

 

 

 

 

 

Vocoder is entered by choosing the appropriate option in “Choice 1”. The last Vocoder

 

 

 

 

 

 

 

 

 

 

 

is entered by choosing the appropriate option in “Choice 8”.

 

 

 

 

 

 

 

 

 

 

 

 

Vocoder types can also be changed per call basis by using a star code. Please see the

 

 

 

 

 

 

 

 

 

 

 

“Call features” section.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G723 Rate

 

 

 

Default is 6.3kbps. Defines the encoding rate for G.723.1 vocoder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

iLBC Frame Size

 

 

 

Default is 20ms. Sets the iLBC frame size in 20ms or 30ms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

iLBC Payload type

 

 

 

Defines payload type for iLBC. Default value is 97. The valid range is between 96 and

 

 

 

 

 

 

 

 

 

127.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VAD

 

 

 

Default is No. VAD allows detecting the absence of audio and conserve bandwidth by

 

 

 

 

 

 

 

 

 

preventing the transmission of "silent packets" over the network.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grandstream Networks, Inc.

 

 

HT-70X User Manual

Page 28 of 35

 

 

 

 

 

 

 

Firmware Version 1.0.0.18

Last Updated: 03/2012

Image 28
Contents Grandstream Networks, Inc HT701 HT702Onfiguring the HT70X Through V Oice P Rompts Configuration GUI Interface Examples Warranty Safety CompliancesWelcome Connect Your HT70X Connecting the HT70XEquipment Packaging Definitions of the HT70X Connectors Power LEDBasic Definitions of the HT70X LEDs Pattern HT702 HT704Advanced Definitions of the HT70X LEDs Pattern Analog HT70X Software Features Software Features OverviewProduct Overview HT70X Hardware and Technical Specifications Hardware SpecificationEMC Understanding HT70X Voice Prompt Basic OperationsHT70X IVR Menu Definitions Using IVR Using Star CodePlacing a Phone Call ExamplesCall Hold Call WaitingCall Transfer Or Voice Prompt with option 47, then 192*168*0*160Way Conferencing Fax SupportAttended Transfer Instructions for 3-way conferenceCall Features HT70X Call FeaturesEnable Srtp Disable Srtp Blind TransferConfiguring the HT70X through Voice Prompts Configuration GuideConfiguring the HT70X Via Web Browser Important Settings NAT SettingsBasic Settings MTZ+6MDT+5 StatusNAT Advanced User Configuration Advanced SettingsDND FXSHTTP/HTTPS ACS URL URISyslog Level Primary RadiusAccount Settings Unregister on Reboot Enable Ring-Transfer Disable Bellcore Style SIP T1 TimeoutDisable Dtmf Enable Call FeaturesDisable Call Waiting Disable Call-WaitingNo Key Entry Timeout Early DialDial Plan Prefix Use # as Dial KeyVAD Fax Mode Detection ModeSrtp Mode Slic SettingSaving the Configuration Changes HT704 FXS Ports SettingsRebooting the HT70X from Remote Configuration through a Central Server Firmware Upgrade through TFTP/HTTP/HTTPS Software UpgradeInstructions for Upload from Local Directory Instructions for local firmware upgrade using Tftp server Configuration File DownloadFirmware and Configuration File Prefix and Postfix Managing Firmware and Configuration File DownloadYes, every Restore Factory Default Setting Encode the MAC Address
Related manuals
Manual 52 pages 18.05 Kb