Powermatic WP2412 operating instructions Troubleshooting Mechanical & Electrical Problems

Page 16

Troubleshooting: Mechanical & Electrical Problems

Trouble

Board thickness does not match digital display

Chain jumping

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

Digital display not calibrated properly.

Follow calibration procedures.

 

 

Inadequate chain tension.

Adjust chain tension.

 

 

Sprockets misaligned.

Align sprockets.

 

 

Sprockets worn.

Replace sprockets.

 

 

No incoming power.

Verify unit is connected to power, and

main switch is set to “I”.

 

 

 

 

When planer overloads on the circuit

 

breaker built into the motor starter, it

 

takes time for the machine to cool

Overload automatic reset has not

down before restart. Allow unit to

reset.

adequately cool before attempting

 

restart. If problem persists, check

 

amp setting on the motor starter

 

inside the electrical enclosure.

 

 

 

One cause of overloading trips which

 

are not electrical in nature is too

 

heavy a cut. The solution is to take a

 

lighter cut. If too deep a cut is not the

 

problem, then check the amp setting

Planer frequently trips.

on the overload relay. Match the full

 

load amps on the motor as noted on

 

the motor plate. If amp setting is

 

correct then there is probably a loose

 

electrical lead. Check amp setting on

 

motor starter.

 

 

 

Verify that planer is on a circuit of

Building circuit breaker trips or fuse

correct size. If circuit size is correct,

there is probably a loose electrical

blows.

lead. Check amp setting on motor

 

 

starter.

 

 

 

Go through all the electrical

 

connections on the planer including

 

motor connections, verifying the

Loose electrical connections.

tightness of each. Look for any signs

 

of electrical arcing which is a sure

 

indicator of loose connections or

 

circuit overload.

 

 

 

Examine motor starter for burned or

 

failed components. If damage is

 

found, replace motor starter. If motor

 

starter looks okay but is still suspect,

Motor starter failure.

you have two options: Have a

 

qualified electrician test the motor

 

starter for function, or purchase a new

 

starter and establish if that was the

 

problem on changeout. (continued)

 

 

16

Image 16
Contents Inch Wood Planer Part No. M-0460285Warranty and Service More Information WMH Tool Group WarrantyTable of Contents Page Page Specifications Introduction DescriptionWP2412 Planer Dimensions Contents of the Shipping Container UnpackingTools required for installation InstallationElectrical Connections Adjustments Starting procedureDust Collection ControlsCalibrating Digital Display Changing Knives Changing FusesDo not loosen any screws on the cutterhead Belt Tension & Replacement Drive Chain ReplacementFeed Rollers MaintenanceTable Rollers Trouble Troubleshooting Operating ProblemsProbable Cause Remedy Troubleshooting Mechanical & Electrical Problems If you have access to a voltmeter, you Replacement Parts Parts List Drawing No Index No. Part No Description SizeIndex No. Part No Description Drawing No TS-1541041 Drawing No WP2412-301 Main Bearing Housing, Left BB6209V Drawing No WP2412-401 Hood Handle WP2412-121 Drawing No WP2412-501 Main Motor 15HP, 230V, 3Ph WP2412-502 Drawing No Parts List Electrical Box Electrical Box Parts List Control Panel Electrical Connections 230 Volt Electrical Connections 230 Volt Page WMH Tool Group