Powermatic WP2412 operating instructions If you have access to a voltmeter, you

Page 17

Trouble

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

 

If you have access to a voltmeter, you

 

can separate a starter failure from a

 

motor failure by first, verifying

 

incoming voltage at 220+/-20 and

 

second, checking the voltage

Motor starter failure.

between starter and motor at 220+/-

20. If incoming voltage is incorrect,

 

 

you have a power supply problem. If

 

voltage between starter and motor is

 

incorrect, you have a starter problem.

 

If voltage between starter and motor

 

is correct, you have a motor problem.

 

 

 

If electric motor is suspect, you have

 

two options: Have a qualified

Motor failure.

electrician test the motor for function

or remove the motor and take it to a

 

 

qualified electric motor repair shop

 

and have it tested.

 

 

 

Double check to confirm all electrical

 

connections are correct and properly

 

tight. The electrical connections other

 

than the motor are pre-assembled

Miswiring of the unit.

and tested at the factory. Therefore,

the motor connections should be

 

 

double checked as the highest

 

probability for error. If problems

 

persist, double check the factory

 

wiring.

 

 

 

If the on/off switch is suspect, you

 

have two options: Have a qualified

On/off switch failure.

electrician test the switch for function,

or purchase a new on/off switch and

 

 

establish if that was the problem on

 

changeout.

 

 

17

Image 17
Contents Part No. M-0460285 Inch Wood PlanerMore Information WMH Tool Group Warranty Warranty and ServiceTable of Contents Page Page Introduction Description SpecificationsWP2412 Planer Dimensions Unpacking Contents of the Shipping ContainerElectrical Connections InstallationTools required for installation Starting procedure AdjustmentsDust Collection ControlsCalibrating Digital Display Do not loosen any screws on the cutterhead Changing FusesChanging Knives Drive Chain Replacement Belt Tension & ReplacementTable Rollers MaintenanceFeed Rollers Probable Cause Remedy Troubleshooting Operating ProblemsTrouble Troubleshooting Mechanical & Electrical Problems If you have access to a voltmeter, you Replacement Parts Index No. Part No Description Size Parts List Drawing NoIndex No. Part No Description Drawing No TS-1541041 Drawing No WP2412-301 Main Bearing Housing, Left BB6209V Drawing No WP2412-401 Hood Handle WP2412-121 Drawing No WP2412-501 Main Motor 15HP, 230V, 3Ph WP2412-502 Drawing No Parts List Electrical Box Electrical Box Parts List Control Panel Electrical Connections 230 Volt Electrical Connections 230 Volt Page WMH Tool Group