PHOTOMETRICS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| I8 | |
| Coefficients of Utilization |
|
|
|
|
|
|
|
|
|
|
| C a n d e la |
|
| |||||||||
|
| Effective floor cavity reflectance |
| 20% |
|
|
|
|
|
|
|
| Angle | Along II | 45° | Across | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| rc |
| 80% |
|
| 70% |
|
| 50% |
| 30% |
|
| 10% |
| 0% | 0 | 3547 | 3547 | 3547 | ||||
| rw | 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 | |||||
| 5 | 3526 | 3528 | 3516 | ||||||||||||||||||||
| RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | 3477 | 3393 | 3233 | ||
| 0 | 113 113 | 113 | 113 | 110 | 110 | 110 | 110 | 104 | 104 | 104 | 98 | 98 | 98 | 93 | 93 | 93 | 90 | ||||||
| 15 | 3394 | 3104 | 2822 | ||||||||||||||||||||
| 1 | 104 | 99 | 95 | 92 | 100 | 97 | 93 | 90 | 91 | 88 | 86 | 87 | 84 | 82 | 82 | 80 | 79 | 76 | |||||
| 20 | 3281 | 2757 | 2455 | ||||||||||||||||||||
| 2 | 95 | 87 | 81 | 75 | 91 | 85 | 79 | 74 | 80 | 75 | 71 | 76 | 72 | 69 | 73 | 69 | 66 | 64 | |||||
| 25 | 3138 | 2426 | 2159 | ||||||||||||||||||||
| 3 | 86 | 77 | 69 | 63 | 84 | 75 | 68 | 62 | 71 | 65 | 60 | 68 | 63 | 59 | 65 | 60 | 57 | 55 | |||||
| 30 | 2967 | 2149 | 1921 | ||||||||||||||||||||
| 4 | 79 | 68 | 60 | 54 | 77 | 67 | 59 | 53 | 64 | 57 | 52 | 61 | 55 | 51 | 58 | 53 | 49 | 47 | |||||
| 35 | 2771 | 1873 | 1698 | ||||||||||||||||||||
| 5 | 73 | 61 | 53 | 47 | 71 | 60 | 52 | 46 | 57 | 51 | 45 | 55 | 49 | 44 | 52 | 47 | 43 | 41 | |||||
| 40 | 2548 | 1640 | 1486 | ||||||||||||||||||||
| 6 | 68 | 56 | 47 | 41 | 66 | 54 | 47 | 41 | 52 | 45 | 40 | 50 | 44 | 39 | 48 | 43 | 38 | 36 | |||||
| 45 | 2305 | 1415 | 1317 | ||||||||||||||||||||
| 7 | 63 | 51 | 42 | 37 | 61 | 50 | 42 | 36 | 48 | 41 | 36 | 46 | 40 | 35 | 44 | 39 | 34 | 33 | |||||
| 50 | 2041 | 1196 | 1266 | ||||||||||||||||||||
8 | 59 | 46 | 38 | 33 | 57 | 45 | 38 | 33 | 44 | 37 | 32 | 42 | 36 | 32 | 41 | 35 | 31 | 29 | ||||||
55 | 1759 | 1021 | 1196 | |||||||||||||||||||||
Electronic Ballast | ||||||||||||||||||||||||
9 | 55 | 43 | 35 | 30 | 54 | 42 | 35 | 30 | 40 | 34 | 29 | 39 | 33 | 29 | 38 | 32 | 28 | 27 | ||||||
60 | 1465 | 945 | 1097 | |||||||||||||||||||||
| ||||||||||||||||||||||||
10 | 52 | 40 | 32 | 27 | 50 | 39 | 32 | 27 | 38 | 31 | 27 | 36 | 31 | 26 | 35 | 30 | 26 | 24 | ||||||
65 | 1160 | 842 | 953 | |||||||||||||||||||||
2750 Lumens | Zonal Lumen Summary |
|
|
|
|
|
|
|
|
|
|
|
| 70 | 853 | 709 | 769 | |||||||
Spacing criterion: |
|
|
|
|
|
|
|
|
|
|
|
| 75 | 552 | 528 | 581 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
(II) 1.2 x mounting | Zone | Lumens | %Lamp | %Fixture |
|
|
|
|
|
|
|
|
|
| 80 | 270 | 334 | 271 | ||||||
height, ( ) 0.9 x |
|
|
|
|
|
|
|
|
|
| 85 | 51 | 64 | 17 | ||||||||||
2384 |
| 28.9 |
| 30.0 |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 90 | 0 | 3 | 1 | ||||||||
mounting height |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
3656 |
| 44.3 |
| 46.1 |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
Efficiency 96.2% | 5946 |
| 72.1 |
| 74.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Test Report: | 7451 |
| 90.3 |
| 93.9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 7935 |
| 96.2 |
| 100.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
I8332UNVUPL.IES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LER =
Yearly Cost of 1000 lumens, 3000 hrs at
.08 KWH = $2.54
SHIPPING INFORMATION
Catalog No. | Wt. |
15 lbs. | |
30 lbs. | |
|
|
ORDERING INFORMATION
S A M P L E N U M B E R : 8TI8 - 332 - EB82/PLUS - UPL - U
Length
Blank=4' Length
8T=8' Length
Series
I8=T8 Industrial
Mounting Arrangement
Blank=Stand Alone
R=Continuous Row Mount
No. of Lamps
3=3 Lamps
Lamp Type
32=32W T8 (4') Lamps
Distribution Optic
Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White)
Shielding Options
Blank=Open
TBW=Thin White Baffle
FL=Frosted Acrylic Lens & Frame(2)
CL=Clear Acrylic Lens & Frame
ASY= Asymmetric Directional Louver(2)
WG=Heavy Duty Wireguard
Voltage(3)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Options
I8 Lamps Installed
L8830=T8 Lamp, 85CRI 3000K
L8835=T8 Lamp, 85CRI 3500K
L8841=T8 Lamp, 85CRI 4100K
L8850=T8 Lamp, 85CRI 5000K
GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed(3)
Ballast Type
T8 Systems
EB8 =T8 Electronic Instant Start.(4) Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start.(4)
High Ballast Factor >1.15.
No. of Ballast Total Harmonic Distortion < 10% 1, 2 or 3
ER8 =T8 Electronic Program Rapid Start.(4) Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
ER8 /PLUS= T8 Electronic Program Rapid Start.
|
|
|
| High Ballast Factor >1.15. |
| No. of | Total Harmonic Distortion < 10% | ||
| Ballast | |||
|
| |||
| 1, 2 or 3 |
| ||
DIM=Consult Factory(9) |
|
|
|
|
|
|
Options | Packaging | ||||
NUA=No Uplight Apertures In Housing | U=Unit Pack | ||||
(Cannot be combined w/UPL) | PAL=Palletized | ||||
UPL=Uplight Apertures | Out of Carton | ||||
PALC=Palletized | |||||
(see ordering information) | In Carton | ||||
TILW=Tandem Inline Wiring |
|
|
|
|
|
MWS=Modular Wiring System
MS=Aisle Coverage Motion Sensor(5)
MSO=360° Coverage Motion Sensor(5)
C3=3' Power Cord
C6=6' Power Cord
MP=Modular Power Receptacle(1) (3)
TCBP=Top Connector Box Plate(6)
Accessories (order separately) TCB=Top Connector Box
GRIPPLE
GRIPPLE LOOP- =Loop Hanger, #2 Cable (Specify 10' or
NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs. (2)Use with wide distribution optic only. (3)Voltage must be specified when ordered with plugs, motion sensors or emergency ballasts. (4)ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configurations. (5)Specify voltage. (6)For use with Top Connector Box options. See accessories. (7)TAP option available with a maximum of two ballasts, including EM battery pack. (8)Not for use in gymnasiums or similar recreational facilities. (9)Dimming ballast must be specified at time of order.
30')
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify Voltage)
Door Frames (for Field Installation)
BAFFLE 4FT I8 (White) 11571919=Thin White Blade
Baffle (I8)
BAFFLE 4FT I8=Thin White Blade Baffle (I8) 90801PPK=Asymmetrical Directional Louver
Specifications and Dimensions subject to change without notice. | ADF042290 |
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 | 08/02/2008 3:00:44 PM |