Giant P210, P209, P211, P205, P208, P206 Specifications Model P207, P207 Horsepower Requirements

Page 5
HP = (GPM X PSI) / 1450

Specifications

Model P207

1750 RPM+

U. .S.

Metric

Flow (Continuous) @ 2000 PSI (140 Bar)

0.9 GPM

3.4 L/min

Flow (Intermittent) @ 2500 PSI (175 Bar)

0.9 GPM

3.4 L/min

3450 RPM+

 

 

Flow (Continuous) @ 2000 PSI (140 Bar)

1.7 GPM

6.4 L/min

Flow (Intermittent) @ 2000 PSI (140 Bar)

1.7 GPM

6.4 L/min

Maximum Inlet Pressure

145 PSI

10 Bar

Plunger Diameter

0.47”

12 mm

Stroke

0.25”

6.3 mm

Max. Temperature of Pumped Fluids

160o F

70o C

Inlet Ports

(2) 1/2" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

0.98”

24 mm

Key Width

0.31”

8 mm

Shaft Mounting

Right Side Facing Manifold

Weight

11.7 lbs

5.3 Kg

Crankcase Oil Capacity

7.5 fl.oz

0.22 Liters

Extended Crankcase Oil Capacity

9.0 fl.oz

0.27 Liters

Volumetric Efficiency @ 1750 RPM

0.94

Volumetric Efficiency @ 3450 RPM

0.87

Mechanical Efficiency @ 3450 RPM

0.86

+Positive inlet pressure required

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

 

 

In order to drive the pump from the side opposite the present shaft

 

 

extension, simply remove the valve casing from the crankcase and

 

 

rotate the pumps 180 degrees to the desired position. Be certain to

 

 

rotate the seal case (item #20) as well, so that the weep holes are

 

 

down at the six o'clock position. Exchange the oil fill and the oil

 

 

drain plugs, also. Refer to the repair instructions as necessary for

 

 

the proper assembly sequence.

 

HORSEPOWER RATINGS:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The rating shown are the power

 

 

 

 

 

 

 

 

requirements for the pump. Gas

 

P207 HORSEPOWER REQUIREMENTS

 

engine power outputs must be

 

RPM

GPM

1000 PSI

 

1500 PSI

2000 PSI

2500 PSI*

 

 

approximately twice the pump

 

500

0.26

0.2

 

0.3

0.4

0.4

 

 

power requirements shown above.

 

1000

0.51

0.4

 

0.5

0.7

0.9

 

 

 

 

1750

0.90

0.6

 

0.9

1.2

1.6

We recommend a 1.15 service factor

 

3000

1.48

1.0

 

1.5

2.0

2.6

 

3200

1.58

1.1

 

1.6

2.2

2.7

be specified when selecting an

 

3450

1.70

1.2

 

1.8

2.3

2.9

electric motor as the power source.

*Intermittent duty only

 

 

 

To compute specific pump horse

 

 

 

power requirements, use the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

following formula:

5

Image 5 Contents
Series Installation Instructions P205 Horsepower Requirements SpecificationsP206 Horsepower Requirements Specifications Model P206P207 Horsepower Requirements Specifications Model P207P208 Horsepower Requirements Specifications Model P208P209 Horsepower Requirements Specifications Model P209P210 Horsepower Requirements Specifications Model P210P211 Horsepower Requirements Specifications Model P211Exploded View P205/P206/P207/P208/P209/P210/P211 P205/P206/P207/P208/P209/P210/P211 Parts List P205/P206/P207/P208/P210/P211 Torque Specifications Repair Instructions P205/P206/P207/P208/P209/P210/P211 Pumps Check Daily Weekly 50hrs Every P205/P206/P207/P208/P209/P210/P211 Dimensions Inches mm Giant Industries Limited Warranty