Giant P210, P209, P205, P208, P207, P206 Specifications Model P211, P211 Horsepower Requirements

Page 9

Specifications

Model P211

1750 RPM+

U. .S.

Metric

Flow (Continuous) @ 2000 PSI (140 Bar)

2.1 GPM

7.9 L/min

Flow (Intermittent) @ 2500 PSI (175 Bar)

2.1 GPM

7.9 L/min

3450 RPM+

 

 

Flow (Continuous) @ 2000 PSI (140 Bar)

3.8 GPM

14.4 L/min

Flow (Intermittent) @ 2000 PSI (140 Bar)

3.8 GPM

14.4 L/min

Maximum Inlet Pressure

145 PSI

10 Bar

Plunger Diameter

0.47”

12 mm

Stroke

0.56”

14.2 mm

Max. Temperature of Pumped Fluids

160o F

70o C

Inlet Ports

(2) 1/2" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

0.98”

24 mm

Key Width

0.31”

8 mm

Shaft Mounting

Right Side Facing Manifold

Weight

11.7 lbs

5.3 Kg

Crankcase Oil Capacity

7.5 fl.oz

0.22 Liters

Extended Crankcase Oil Capacity

9.0 fl.oz

0.27 Liters

Volumetric Efficiency @ 1750 RPM

0.94

Volumetric Efficiency @ 3450 RPM

0.87

Mechanical Efficiency @ 3450 RPM

0.86

+Positive inlet pressure required

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P211 HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*

500

0.60

0.4

0.6

0.8

1.0

1000

1.20

0.8

1.2

1.7

2.1

1750

2.10

1.4

2.2

2.9

3.6

3000

3.30

2.3

3.4

4.6

5.7

3200

3.52

2.4

3.6

4.9

6.1

3450

3.80

2.6

3.9

5.2

6.5

*Intermittent duty only

HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

9

Image 9 Contents
Series Installation Instructions P205 Horsepower Requirements SpecificationsP206 Horsepower Requirements Specifications Model P206P207 Horsepower Requirements Specifications Model P207P208 Horsepower Requirements Specifications Model P208P209 Horsepower Requirements Specifications Model P209P210 Horsepower Requirements Specifications Model P210P211 Horsepower Requirements Specifications Model P211Exploded View P205/P206/P207/P208/P209/P210/P211 P205/P206/P207/P208/P209/P210/P211 Parts List P205/P206/P207/P208/P210/P211 Torque Specifications Repair Instructions P205/P206/P207/P208/P209/P210/P211 Pumps Check Daily Weekly 50hrs Every P205/P206/P207/P208/P209/P210/P211 Dimensions Inches mm Giant Industries Limited Warranty