Operating Instructions

2nd F Operation

1

Press the Start/Stop button.

 

 

The unit will respond with

 

beep sound.

Open the door of the Remote Controller and press the 2nd F

2 button to operate functions printed in blue at bottom of buttons.

(Check the indication of 2nd function on Remote Controller display.)

These buttons operate the timer setting as follows:

CANCEL

ONOFF SET

AUTO CLEAN

CANCEL

ONOFF SET

AUTO CLEAN

3

2nd function goes off in a short time automatically or when the button is pressed again.

For more details, refer to functions next page.

Owner's Manual 17

Image 17
Contents Heat CONTROLLER, INC Table of Contents Install the panel and the cover of control box securely Safety PrecautionsService Center For electrical work, contactBe cautious when unpacking and installing the product Do not modify the power cableBe sure the installation area does not deteriorate with age Do not handle the pipe by yourselfCostomerFlooded or submerged Power supply cable Service CenterContact an Authorized Be cautious that water does not enter the productProperly That water is drained awayBad connection may cause To avoid vibration Water leakage Use two or more people to lift and transport the productWhen cleaning or Use a soft cloth to clean. DoDo not block the inlet or outlet of air flow Not use harsh detergentsPrior to operation Operating Instructions Remote ControllerStorage and Tips For Using the Remote Controller Signal Receptor Signal transmitter Remote Control OperationPressed and stops when the button is pressed again Nd F ButtonCooling Operation Set the temperature lower than the room temperatureAuto Operation Temperature and fan speed are automatically set bySound Fan speed mode is shiftedHealthy Dehumidification Operation Heating OperationHeat pump model only Temperature can be set within a rangeBeep sound 16C~30C60F~86F in 1C2F incrementsOr or Unit will operate in high fan speed in cooling/heating modeJet Cool 2nd F Operation Sleep Mode Additional featuresSetting the Time Delay Start/Pre-Set StopVertical Airflow Direction Control Air Circulation ModeAuto restart Forced OperationHeat pump Model Fan speed and cooling capacityStandard Type Indoor Unit Maintenance and ServiceReplacement of purifying filter Optional Clean the air filter regularly When the air conditioner is to be used againDo not overcool the room Keep blinds or curtains Closed UniformProblem Explanation See TroubleshootingMemo Wall Mounted Multi-Zone Split System Air Conditioner 13-08 No A22236J
Related manuals
Manual 28 pages 40.65 Kb

MMH24DA-1, MMC24DA-1, MMC36TA-1, MMH36TA-1, MMC18DA-1 specifications

The Heat Controller series, including models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1, represents a robust line of heating and cooling solutions designed for efficiency, reliability, and user comfort. These models are popular choices for both residential and light commercial applications, offering a blend of advanced technology and user-friendly features.

One of the standout features of these units is their energy efficiency. Each model is engineered to minimize energy consumption while maximizing heating and cooling capacities. The incorporation of SEER and HSPF ratings allows users to evaluate the energy performance of these units, ensuring they make an environmentally responsible choice that helps reduce energy costs.

Technologically, the Heat Controller units utilize inverter technology, which enables the system to adjust the compressor speed based on the required heating or cooling output. This leads to a more consistent indoor temperature and reduces wear and tear on the system, promoting longevity. Additionally, the quiet operation of these units makes them ideal for residential settings where noise can be a concern.

The MMC and MMH models also come equipped with advanced climatic control capabilities. Many units feature programmable thermostats that allow users to set schedules, thereby optimizing energy usage during peak and off-peak hours. These smart controls can be easily adjusted via user-friendly interfaces, ensuring that comfort is just a click away.

Durability and reliability are other hallmarks of the Heat Controller series. The outdoor units are designed to withstand harsh weather conditions, featuring a robust build that includes protective coatings to guard against corrosion and other environmental challenges. Moreover, the compressors used in these models are crafted for maximum efficiency, ensuring that they deliver reliable performance year after year.

Installation flexibility is another key benefit. These heating and cooling systems can be installed in various configurations, making them suitable for a range of settings, from tight urban spaces to larger commercial environments.

With a commitment to quality and customer satisfaction, Heat Controller models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1 cater to diverse heating and cooling needs, harnessing technology and design to enhance user comfort and efficiency in any environment.