Heat Controller MMC18DA-1, MMC24DA-1, MMH36TA-1 Forced Operation, Auto restart, Heat pump Model

Page 20

Additional features

Forced Operation

The operation will be started operation if the power button is pressed without remote controller. If you want to stop operation, re-press the button.

ON/OFF

ON/OFF

button

button

 

Cooling Model

 

Heat pump Model

 

 

 

 

 

 

Room Temp. 24°C(76°F)

21°C(70°F) Room Temp. < 24°C(76°F)

Room Temp. < 21°C(70°F)

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

 

 

 

 

 

Setting Temperature

22°C(72°F)

22°C(72°F)

23°C(74°F)

24°C(76°F)

 

 

 

 

 

Auto restart

In case the power comes on again after a power failure, the unit operates automatically based on the previous operating conditions.

So there is no need to activate this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts about 3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

In case of absence for a long time while power failure, turn off main power to avoid undersired Auto restart.

NOTICE

This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp(2) will blink 4 times.

To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator lamp(1) will blink 4 times.

ON/OFF

ON/OFF

button

button

Helpful information

Fan speed and cooling capacity.

The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium

fan speed.

High fan speed is recommended when you wish to cool/heat the room quickly.

High

Speed

High

Speed

20Wall Mounted Multi-Zone Split System Air Conditioner

Image 20
Contents Heat CONTROLLER, INC Table of Contents Safety Precautions Install the panel and the cover of control box securelyService Center For electrical work, contactDo not modify the power cable Be cautious when unpacking and installing the productBe sure the installation area does not deteriorate with age Do not handle the pipe by yourselfCostomerPower supply cable Service Center Flooded or submergedContact an Authorized Be cautious that water does not enter the productThat water is drained away ProperlyBad connection may cause To avoid vibration Water leakage Use two or more people to lift and transport the productUse a soft cloth to clean. Do When cleaning orDo not block the inlet or outlet of air flow Not use harsh detergentsPrior to operation Operating Instructions Remote ControllerStorage and Tips For Using the Remote Controller Signal Receptor Remote Control Operation Signal transmitterPressed and stops when the button is pressed again Nd F ButtonSet the temperature lower than the room temperature Cooling OperationTemperature and fan speed are automatically set by Auto OperationSound Fan speed mode is shiftedHealthy Dehumidification Operation Temperature can be set within a range Heating OperationHeat pump model onlyBeep sound 16C~30C60F~86F in 1C2F incrementsOr or Unit will operate in high fan speed in cooling/heating modeJet Cool 2nd F Operation Additional features Sleep ModeSetting the Time Delay Start/Pre-Set StopAir Circulation Mode Vertical Airflow Direction ControlForced Operation Auto restartHeat pump Model Fan speed and cooling capacityMaintenance and Service Standard Type Indoor UnitReplacement of purifying filter Optional When the air conditioner is to be used again Clean the air filter regularlyDo not overcool the room Keep blinds or curtains Closed UniformTroubleshooting Problem Explanation SeeMemo Wall Mounted Multi-Zone Split System Air Conditioner 13-08 No A22236J