Heat Controller BDE-123-A, BDE-103-A service manual Complaint Cause Remedy

Page 22

COMPLAINT

CAUSE

REMEDY

 

 

 

 

Compressor cycles

Voltage

Check the voltage. See the limits on the preced-

on overload.

 

ing page. If not within limits, call an electrician.

 

 

 

 

 

Overload

Check overload, if externally mounted.

 

 

Replace if open. (If the compressor temperature

 

 

is high, remove the overload, cool, and retest.)

 

 

 

 

 

Fan motor

If not running, determine the cause. Replace if

 

 

required.

 

 

 

 

 

Condenser air flow

Remove the cabinet. inspect the interior surface

 

restriction

of the condenser; if restricted, clean carefully

 

 

with a vacuum cleaner (do not damage fins) or

 

 

brush. Clean the interior base before

 

 

reassembling.

 

 

 

 

 

Condenser fins

If condenser fins are closed over a large area

 

(damaged)

on the coil surface, head pressures will increase,

 

 

causing the compressor to cycle. Straighten the

 

 

fins or replace the coil.

 

Capacitor

Test capacitor.

 

 

 

 

 

Wiring

Check the terminals. If loose, repair or replace.

 

Refrigerating system

Check the system for a restriction.

Insufficient cooling or

Air filter

If restricted, clean of replace.

heating

Exhaust damper door

Close if open.

 

 

 

 

 

Unit undersized

Determine if the unit is properly sized for the area to

 

 

 

be cooled.

Excessive noise.

Blower or fan

Check the set screw or clamp. If loose or missing,

 

 

correct. If the blower or fan is hitting air guide,

 

 

rearrange the air handling parts.

 

Copper tubing

Remove the cabinet and carefully rearrange tubing

 

 

not to contact cabinet, compressor, shroud, and

 

 

barrier.

 

 

 

 

— 22—

Image 22 Contents
Models BDE-103-A BDE-123-AContents PrefaceSpecifications For BDE-103-A/BDE-123-ACooling only Model Operation FeaturesControl Locations VentilationCooling and Heating Model Operation Heat Pump ModelsFront Grille Disassembly InstructionsMechanical Parts CabinetORIFICE, Heater Assy and Turbo FAN AIR Handling Parts2 FAN Motor Electrical PartsShroud CompressorRotary Switch Power CordThermostat Evaporator Refrigeration CycleCondenser Capillary TubePage Pulling Vacuum Dimension of sleeve assembly optional HOW to Install the UnitDimension of air conditioner If YOU Want to Pull OUT the Filter DownwardInstallation Kits Contents Suggested Tool Requirements Sleeve up to 18 inches deepUnit Installation Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramExploded View Model BDE-103-A/BDE-123-AReplacement Parts List Model BDE-103-A/BDE-123-AHeat CONTROLLER, INC