Heat Controller BDE-103-A, BDE-123-A HOW to Install the Unit, Dimension of air conditioner

Page 13

3. INSTALLATION

3.1 HOW TO INSTALL THE UNIT

CAUTION

There are sharp edges that can cause serious cuts.

When lifting the air conditioner, it is HEAVY. Use 2 peoples to lift.

For existing sleeve, you should measure the wall sleeve dimensions.

You can install the new air conditioner according to these installation instructions to achieve the best performence. All wall sleeves used to mount the new air conditioner must be in good structural condition and have the rear grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner.

Dimension of air conditioner

24-21/32"

(626 mm)

14-13/32"

(366 mm)

18"(458 mm)

19-21/32"

(499 mm)

Dimension of sleeve assembly (optional)

To avoid vibration and noise, make sure the unit is installed securely and firmly.

A. BEFORE ATTACHING THE FRONT GRILLE TO THE CABINET, IF YOU WANT TO PULL OUT THE FILTER UPWARD;

1.There should be no obstacle, like a fence, within 20" which might restrict heat radiation from the condenser.

2.To prevent reducing performance, install the unit so that louvers of the cabinet are not blocked.

B. IF YOU WANT TO PULL OUT THE FILTER DOWNWARD;

The grille is already designed for that way.

INSULATION

COOLED

AIR

INTAKE

AIR

1/4" Bubble of the level

25-7/8"

(656 mm)

15- 17/32"

(394 mm)

16-23/32"

(425 mm)

WALL

SLEEVE

 

 

 

HEAT

RADIATION

WALL

Over 20"

 

1.Install the unit a little obliquely outward not to leak the condensed water into the room (about 1/2" or 1/4" bubble with level).

2.Install the unit with its bottom portion 30~60" above the floor level.

3.The power cord must be connected to an independent circuit. The green wire must be grounded.

1/4" Bubble

Level

— 13—

Image 13 Contents
BDE-123-A Models BDE-103-APreface ContentsFor BDE-103-A/BDE-123-A SpecificationsControl Locations FeaturesCooling only Model Operation VentilationHeat Pump Models Cooling and Heating Model OperationMechanical Parts Disassembly InstructionsFront Grille CabinetORIFICE, Heater Assy and Turbo FAN AIR Handling Parts2 FAN Shroud Electrical PartsMotor Compressor Rotary Switch Power Cord Thermostat Condenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Dimension of air conditioner HOW to Install the UnitDimension of sleeve assembly optional If YOU Want to Pull OUT the Filter DownwardInstallation Kits Contents Sleeve up to 18 inches deep Suggested Tool RequirementsUnit Installation Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Circuit Diagram Schematic DiagramModel BDE-103-A/BDE-123-A Exploded ViewModel BDE-103-A/BDE-123-A Replacement Parts ListHeat CONTROLLER, INC