Heat Controller BDE-123-A Features, Control Locations, Cooling only Model Operation, Ventilation

Page 4

1.4 FEATURES

Designed for cooling only.

Powerful and quiet cooling.

Top-down chassis for the simple installation and service.

1.5 CONTROL LOCATIONS

1.5.1COOLING ONLY MODEL

• OPERATION

Side air-intake, side cooled-air discharge.

Built in adjustable THERMOSTAT.

Washable one-touch filter.

Compact size.

Operation

 

Off

- Turns air conditioner off.

 

Off

 

 

 

 

 

Med Fan

- Med speed fan operation without cooling.

Med

 

 

High

 

 

Low Fan

- Low speed fan operation without cooling.

Fan

 

 

Cool

 

 

 

 

High Cool - Cooling with high speed fan operation.

Low

 

 

Med

Med Cool

- Cooling with med speed fan operation.

 

 

Low Cool

- Cooling with low speed fan operation.

Fan

Low Cool

 

Cool

 

 

 

 

 

 

 

 

Thermostat

 

 

 

 

C

 

 

 

 

 

o

 

 

 

 

5

ol

 

 

 

 

r

 

 

4

 

6

e

This automatically controls the temperature of the indoor air.

 

 

37 Turn the knob so that arrow points to the larger marks for

2

8

greater cooling. Point the arrow to the smaller marks for more moderate cooling.

(i.e. the higher number, the greater cooling)

 

 

19

VENTILATION

The ventilation lever is located in the right of the air discharge.

The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.

When fresh air is necessary in the room, set the ventilation lever to the OPEN position.

The damper is opened and room air is exhausted outside.

PULL OPEN / PUSH CLOSE

• ENERGY SAVER (optional)

On : Both the fan and the compressor turn on and turn off together while operation knob is set to the Cool position.

You can get the more economical operation.

Off : The fan runs constantly while operation knob is set to the Cool position.

You can access the Energy Saver switch when you open the inlet grille.

Energy Saver

Off

 

 

 

On

 

 

 

 

 

 

 

 

 

 

 

 

 

—4—

Image 4 Contents
Models BDE-103-A BDE-123-AContents PrefaceSpecifications For BDE-103-A/BDE-123-AFeatures Control LocationsCooling only Model Operation VentilationCooling and Heating Model Operation Heat Pump ModelsDisassembly Instructions Mechanical PartsFront Grille CabinetORIFICE, Heater Assy and Turbo FAN AIR Handling Parts2 FAN Electrical Parts ShroudMotor CompressorRotary Switch Power CordThermostat Refrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum HOW to Install the Unit Dimension of air conditionerDimension of sleeve assembly optional If YOU Want to Pull OUT the Filter DownwardInstallation Kits Contents Suggested Tool Requirements Sleeve up to 18 inches deepUnit Installation Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramExploded View Model BDE-103-A/BDE-123-AReplacement Parts List Model BDE-103-A/BDE-123-AHeat CONTROLLER, INC