Haier HCFU-28C13, HCFU-18C13, HCFU-42CA13 operation manual Comfortable Sleep

Page 18

GUIDE TO OPERATION

Comfortable Sleep

At night, before going to bed you can press down the SLEEP button on the controller and the air-conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.

Press SLEEP button once to make the air conditioner have the previous-set sleep time (first power-on is "1h"), the sleep symbol will appear. Press time button /, you can choose the time in 1~8 hours. Each press of /, the time increases/reduces 1 hour and "Xh" appears in the temperature setting part, "OFF" appears in "TIMER OFF" display part and timer-off time; press SLEEP button again to cancel sleep function, the sleep symbol diappears.

In cooling, dehumidifying mode

One hour after sleeping operation start, the temp. is 1C higher than the setting one. After another hour the temp. rises 1C and then run continuously for another 6hrs' and then close. The actual temp. is higher than the setting one which is to prevent from being too cool to your sleep.

In heating mode

One hour after start up, the temp. decrease 2C lower than the setting one. After another hour decrease by more 2C .

The temperature will automatically rise by 1C after another 3hrs' operation, and then automatically close after 3hrs' continuous operation.

The actral temperature is lower than the setting one which is to prevent from being too hot to your sleep.

OFF

AM

TEMP

 

ON

 

SWING

OFF

FAN

MODE

 

 

CLOCK

 

SET

TIMER

 

SLEEP

LOCK

RESET

 

Note:

In AUTO mode, unit will run in SLEEP function according to the operation mode.

After setting SLEEP function, it is forbidden to calibrate clock.

If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time is complete.

Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER-ON function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first, the TIMER function can not be set.

After setting SLEEP, press CLOCK button to show the time; press TEMP. button to show the temperature; press again to change temperature.

SETTING T

 

SHUT DOWN

1 hr

decrease 2 C

 

 

 

 

1 hr

 

 

decreases 2 C

 

 

about 3 hrs

 

3 hrs

increase1 C

SLEEP RUN BEGINS

SLEEP RUN STOPS

SLEEP RUN BEGINS

SLEEP RUN STOPS

 

 

about 6 hrs

 

1 hr

increase 1 C

1 hr

increase 1 C

 

 

SETTING T

 

SHUT DOWN

Heat mode

Cooling mode

16

Image 18
Contents Operation Manual Contents Disposal of the old air conditioner Specifications Safety Precautions Features and Functions Automatic OperationName of Parts For seriesIntroduction to Spare Parts OperationClock set HintsInstallation LocationRemote Controller Operation Guide to Operation FAN operationSelect temp.setting Auto run, COOL,HEAT and DRY operationRecommendations Air flow direction adjust Fan speed selectionTimer operation Set Clock correctly before starting Timer operationrefer toTimer ON-OFF Adjusting up/down air flow direction Comfortable Sleep Guide to Operation Cleaning and Care Cleaning the Air FilterFollowing four procedures are for series 28,42 Trouble Shooting Followings are not problemsPoor cooling or heating Operating Tips Operation and Performance Heating Performance