When Trouble Happens
Trouble display
Reason | The phenomenon of indicator light on indoor remote receiver | ||
|
|
| |
Room temp. sensor malfunction | "Run" light flashes once | ||
|
|
| |
Indoor coil temp. sensor malfunction | "Run" light flashes twice | ||
|
| ||
Drainage system malfuntion | "Run" light flashes ten times |
| |
|
|
| |
Low pressure protection | "Run"light flashes sixteen times | ||
The exterior alarm signal input | "Run" light flashes eleven times | ||
The defrosting sensor malfunction | "Run" light flashes four times(Heat pump model) | ||
The indoor coil temperature is higher |
|
| |
than room temperature when cooling | "Run" light flashes thirteen times | ||
or the former is lower than the later | |||
|
| ||
when heating |
|
| |
|
|
|
Change-over switch
BM1 | (1) OFF | (2)OFF | |
|
|
| |
| (1) OFF | (2)OFF (Cooling only unit) | |
|
|
| |
BM2 | (1) OFF | (2)ON (Heat pump model) | |
|
| ||
(3) OFF/ON | Heat pump model/Cooling only unit | ||
| |||
|
|
| |
| (4) ON/OFF | Defrost sensor/No defrost sensor | |
|
|
| |
BM3 |
| OFF | |
|
|
| |
BM4 |
| OFF | |
|
|
|
13