STARTING THE AIR CONDITIONER cont.

1.Please put batteries into the remote control.

2.Press POWER once to turn on the air conditioner.

NOTE: When the air conditioner is first plugged in, the LED display will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the temperature 72 F and the fan is automatically set to Quiet speed and the Mode indicator will show ENERGY SAVE.

NOTE: To switch the temperature display between Fahrenheit (F) and Celsius(C), the air conditioner must be plugged in and turned on. On the control panel on the front of the AC, press the UP and DOWN button at the same time and hold for 3 seconds. Press F/C button on remote control to switch between Fahrenheit (F) and Celsius (C).

NOTE: Each time this ENERGY STAR Qualified air conditioner is turned on, it will operate in energy save mode per the EPA requirements. You can select any other mode to satisfy your needs.

3.Select Mode. Refer to “Mode.”

4.Select Speed. Refer to “Speed.”

5.Set Timer. Refer to “Temp/Time”

6.Reset the filter. Refer to “Filter Reset”

MODE

1.Press MODE until you see the indicator light come on next to the desired setting.

2.Choose Fan, Cool, Energy Save, or Dehum.

FAN—Only the fan runs. Press SPEED to select High, Med or Quiet fan speed. The display shows the current room temperature.

NOTE: In fan mode, the temperature cannot be set.

ENERGY SAVE—In this mode the fan runs only when cooling is needed. The fan will run for 3 minute after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the temperature in the room is above the set temperature. The compressor then turns back on.

COOL—Cools the room. Press SPEED to select High, Med, Quiet or Auto Cool fan speed. Press the TEMP/TIME or arrow button to adjust the temperature. The fan will run continuously in cool mode.

DEHUM—Aids in removing humidity from the room. Dehum mode cannot be used to cool room.

NOTE: In Dehum mode, when the set temperature is close to ambient temperature, the compressor may stop and the fan will run in Quiet speed only.

ENGLISH

USING YOUR AIR CONDITIONER

PAGE 15

Image 17
Contents Guide dutilisation et dentretien Page Product Registration Table of ContentsImportant Safety Precautions Read and Follow Safety Instructions Carefully Operational Safety & Warnings Parts Supplied Tools and PartsLocation should Provide Window InstallationLocation Requirements Electrical Requirements Power Supply CordRequired Grounding Method See Electrical RequirementsSee To Test Your Power Supply CordUnpacking the AIR Conditioner Install TOP ChannelPreparing the AIR Conditioner Remove Packaging MaterialsPreparing the AIR Conditioner Install Side CurtainsWidth Preparing the WindowAttach Side Curtains to Window Completing the InstallationStarting the AIR Conditioner Mode Starting the AIR ConditionerSpeed Timer OFFTimer on To View or Change the Remaining Time in Hours Timer OFF To Clear Timer ProgramSleep TEMP/TIMEFilter Reset Using the Remote ControlPower TimerUsing the Remote Control Changing the AIR Direction Cleaning the AIR Filter Customer Service Cleaning the Front PanelNormal Sounds Normal Sounds of AN AIR ConditionerPossible Possible Cause Remedy Problem TroubleshootingONE Year Limited Warranty Limited WarrantyPage Enregistrement DU Produit Table DES MatièresGarantie Limitée FrançaisAvertissement Conservez CES Instructions Utilisation Sécuritaire ET Avertissements Outils Requis Outils ET PiècesInstallation À LA Fenêtre Exigences Relatives À L’EMPLACEMENTCordon Dalimentation Exigences EN Matière DélectricitéCordon Dalimentation consultez la figure Exigences EN Matière D’ÉLECTRICITÉ suiteConsultez la figure Pour Faire Lessai DE Votre Cordon DalimentationDéballage DU Climatiseur Installation DE LA Glissière SupérieurePréparation DU Climatiseur Retrait DES Matériaux DemballagePréparation DU Climatiseur suite Installation DES Panneaux LatérauxRemarques ET Avertissements Préparation DE LA FenêtreFixation DES Panneaux Latéraux À LA Fenêtre Achèvement DE LinstallationDémarrage DU Climatiseur Démarrage DU Climatiseur suite Vitesse Timer OFF Minuterie DE Mise À LarrêtTimer on Minuterie DE Mise EN Marche TEMP/TIME TEMP./DURÉE Pour Effacer LES Réglages Programmés DE LA MinuterieVeille Filter Reset Réinitialisation DU Filtre Utilisation DE LA TélécommandePower Mise EN MARCHE/ARRÊT Timer MinuterieUtilisation DE LA Télécommande Suite Changement DU Sens DE Circulation DE Lair Nettoyage DU Filtre À AIR Nettoyage DU Panneau Avant Service À LA ClientèleSons Normaux Sons Normaux DU ClimatiseurDépannage Problème Possible Causes Possibles SolutionGarantie Limitée DUN AN Garantie LimitéePage Español ÍndiceRegistro DEL Producto Advertencia Guarde Estas Instrucciones Seguridad DE Funcionamiento Advertencias Herramientas Necesarias Herramientas Y PartesInstalación EN UNA Ventana Requerimientos Para LA UbicaciónLA Ubicación Debe Contar CON LO Siguiente Cable DE Suministro Eléctrico Requerimientos EléctricosMétodo Requerido DE Conexión a Tierra Vea la Requerimientos Eléctricos continuaciónNota Para Probar EL Cable DE Suministro EléctricoPreparación DEL Aire Acondicionado Desempaque DEL Aire AcondicionadoRetiro DE LOS Materiales DE Empaque Instalación DE LA Canaleta SuperiorInstalación DE LAS Cortinas Laterales Preparación DEL Aire Acondicionado continuaciónNotas Y Advertencias Preparación DE LA VentanaFije LAS Cortinas Laterales a LA Ventana Finalización DE LA InstalaciónImportante Encendido DEL Aire AcondicionadoModo Encendido DEL Aire Acondicionado continuaciónEncendido DEL Temporizador VelocidadApagado DEL Temporizador Para Borrar EL Programa DEL Temporizador Encedido DEL Aire Acondicionado continuaciónApagado Automático TIEMPO/TEMPERATURARestablecimiento DEL Filtro USO DEL Control RemotoEncendido TemporizadorUSO DEL Control Remoto continuación Cambio DE LA Dirección DEL Aire Limpieza DEL Filtro DE Aire Servicio AL Cliente Limpieza DEL Panel FrontalSonidos Normales Sonidos Normales DE UN Aire AcondicionadoProblema Posible Causa Posible Solución Solución DE ProblemasGarantía Limitada POR UN AÑO Garantía LimitadaHaier America Trading, LLC

ESAQ406P, ESAQ408P specifications

Haier, a renowned brand recognized for innovation in home appliances, has made a significant mark in the air conditioning sector with its ESAQ408P and ESAQ406P models. These units are designed to provide efficient cooling solutions for residential spaces while prioritizing user comfort and energy efficiency.

One of the standout features of the ESAQ408P and ESAQ406P is their impressive energy efficiency ratings. With a SEER (Seasonal Energy Efficiency Ratio) rating that is among the best in the industry, these air conditioners are engineered to consume less energy, helping users save on electricity bills without compromising on performance. Both models utilize eco-friendly refrigerants, further demonstrating Haier’s commitment to sustainable technologies.

Users will appreciate the quiet operation of these air conditioning units. The ESAQ408P and ESAQ406P are designed to operate at low noise levels, making them ideal for bedrooms, offices, or any space where a peaceful environment is paramount. The advanced fan technology reduces operational noise, allowing for an unobtrusive cooling experience.

Another key characteristic of these models is their user-friendly interface. The intuitive remote control allows users to easily adjust temperature settings, fan speed, and modes without hassle. Additionally, the option for Wi-Fi connectivity on these models means users can control their air conditioning remotely through a smartphone app. This feature adds convenience, enabling pre-cooling of spaces before arriving home on hot days.

Both air conditioners come equipped with a self-diagnostic system, ensuring that maintenance and troubleshooting are simple. The units can display error codes on the control panel, making it easier for users to understand when professional maintenance may be needed.

In terms of design, these models boast a sleek and modern aesthetic that can seamlessly integrate into any home decor. Their compact size allows for flexible installation options, making them suitable for various room sizes and configurations.

Overall, the Haier ESAQ408P and ESAQ406P are exemplary models that combine efficiency, advanced technology, and user-centric features, setting a new standard for residential air conditioning. Whether you are looking for dependable cooling solutions for a small apartment or a larger home, these units offer the perfect blend of comfort and cost-effectiveness, catering to the needs of today’s homeowners.