Haier HSU-09RS03/R2(SDB) Specifications, Machine is adaptive in following situation

Page 12

Trouble shooting

Before asking for service, check the following first.

 

Phenomenon

Cause or check points

 

The system

When unit is stopped, it won't restart

 

does not restart

immediately until 3 minutes have

 

immediately.

elapsed to protect the system.

 

 

When the electric plug is pulled out

 

 

and reinserted, the protection circuit

 

 

will work for 3 minutes to protect the

 

 

air conditioner.

 

 

During unit operation or at stop,

 

Noise is heard

a swishing or gurgling noise may

 

be heard.At first 2-3 minutes after

 

 

unit start, this noise is more noticeable.

 

 

(This noise is generated by

 

 

refrigerant flowing in the system.)

 

 

During unit operation, a cracking

 

 

noise may be heard.This noise is

Normal

 

generated by the casing expanding

 

or shrinking because of

Performance

 

temperature changes.

inspection

 

Should there be a big noise from

 

 

air flow in unit operation, air

 

 

filter may be too dirty.

 

 

This is because the system

 

Smells are

circulates smells from the interior

 

generated.

air such as the smell of furniture,

 

 

paint, cigarettes.

 

Mist or steam are

During COOL or DRY operation,

 

blown out.

 

 

indoor unit may blow out mist.

 

 

This is due to the sudden cooling

 

 

of indoor air.

 

In dry mode,fan

In DRY mode, when room temperature

 

becomes lower than temp.

 

speed can’t be

setting+2 oC,unit will run

 

changed.

intermittently at LOW speed

 

 

regardless of FAN setting.

 

 

Is power plug inserted?

 

 

Is there a power failure?

 

 

Is fuse blownout?

 

 

Is the air filter dirty?

 

Poor cooling

Normally it should be cleaned

Multiple

every 15 days.

 

check

 

Are there any obstacles before

 

inlet and outlet?

 

 

 

 

Is temperature set correctly?

 

 

Are there some doors or

 

 

windows left open?

 

 

Is there any direct sunlight

 

 

through the window during the

 

 

cooling operation?(Use curtain)

 

 

Are there too much heat sources

 

 

or too many people in the room

 

 

during cooling operation?

Cautions

Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum:D.B/W.B

32oC/23oC

Cooling

Minimum:D.B/W.B

21oC/15oC

Outdoor

Maximum:D.B/W.B

43oC/26oC

 

Minimum: D.B

18oC

 

Indoor

Maximum:D.B

27oC

Heating

Minimum: D.B

0oC

Outdoor

Maximum:D.B/W.B

24oC/18oC

 

 

Minimum:D.B/W.B -7oC/-8oC

 

Outdoor

Maximum:D.B/W.B

24oC/18oC

 

(INVERTER)

Minimum:D.B

-15oC

2.If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is

broken,change it with the type of T.25A/250V

4.The wiring method should be in line with the local wiring standard.

5.After installation, the power plug should be easily reached.

6.The waste battery should be disposed properly.

7.The appliance is not intended for use by young children or infirm persons without supervision.

8.Young children should be supervised to ensure that they do not play with the appliance.

9.Please employ the proper power plug,which fit into the power supply cord.

10.A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.

11 .The power plug and connecting cable must have acquired the local attestation.

12.In order to protect the units,please turn off the A/C first,and at least 30 seconds later, cutting off the power.

13.Please don't insert any sensor on 3-waystop valve pipe fitting.

12

Image 12
Contents Contents Remote controller Indoor Unit Outdoor UnitLoading of the battery Clock setHint Smart Operation COOL,HEAT and DRY Operation Unit startSmart stops Press TEMP.setting Press Temp buttonFAN Operation 1Up and down air flow direction Left and right air flow directionSetting Cancel Health airflow functionHealth Operation Health Airflow Operation Health airflowPOWER/SOFT Operation Timer Operation To cancel Timer modeSelect your desired operation ModeTemp.setting Unit stop Operation ModeHeat mode Smart mode COOL, DRY mode Heat modeIFP mode IFP OperationECO Operation Display board, unit will unrinClean the filter Fresh OperationRemove the filter Attach the filterProhibition Specifications Machine is adaptive in following situation