Haier HSU-22HEA03/R2, HSU-07HEA03/R2, HSU-09HEA103/R2, 0010516146 Outdoor unit, Connection of pipes

Page 6

Outdoor unit

1.Installation of Outdoor Unit

Install according to Drawing for the installation of indoor and outdoor units

2.Connection of pipes

To bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius should be 30 to 40 mm or longer.

Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A.

Half union

 

 

 

 

 

 

Flare nut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forced fastening without careful centering may damage the threads and cause a leakage of gas.

Spanner

Torque wrench

Pipe Diameter

Fastening torque

 

 

Liquid side 6.35mm(1/4")

18N.m

 

 

Gas side 9.52mm(3/8")

42N.m

 

 

Gas side 12.7mm(1/2")

55N.m

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.

The standard pipe length is 5m. If it is over 7m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant.

B

Outdoor unit

Outdoor unit

Indoor unit

A

A

 

Outdoor unit

 

B

B

Oil trap

 

Indoor unit

A

Indoor unit

 

CAUTION

Max.Elevation: Amax1=10m (07k 09k 12k) Amax2=15m (18k 22k)

In case the elevation A is more than 5m, oil trap shoud be installed every 5~7m

In case A is more than 5m

Max. Length: Bmax1=15m (07k 09k 12k)

Bmax2=25m (18k 22k)

In case the pipe length B is more than 7m,

the refrigerant should be charged, according to 20 g/m.

3.Connection

Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws.

Insert the cable according to terminal number in the same manner as the indoor unit.

4.Attaching Drain-Elbow

If the drain-elbow is used, please attach it as figure.

Note: Only for heat pump unit.

If wiring is not correct, proper operation can not be carried out and controller may be damaged.

Fix the cable with a clamp.

Drain hose

5

Drain elbow

Image 6
Contents Installation Manual of Room Air Conditioner Selection of Installation Place Outdoor Unit Indoor unit Indoor unit Other direction pipingConnecting the indoor/outdoor Electric Cable Outdoor unit Connection of pipesOpen CloseCut pipe Remove burs Insert the flare nut Flare pipeManual de instalación de aparato de aire acondicionado Herramientas necesarias para realizar la instalaciónFuente de alimentación Selección de tuboSelección del lugar de instalación Fijación de la unidad exteriorUnidad interior Unidad interiorAl fijar por primera vez la placa de montaje Entubación en otra dirección Extraer la cubierta del cableado Conexión de los cables eléctricos de interior/exteriorConexión de los tubos Unidad exteriorInstalación de la unidad exterior ConexiónBomba de vacío AbrirPuntos de prueba RebabasAttrezzi necessari per linstallazione Telecomando Batteria secca R-03Alimentazione Scelta del luogo di installazioneScelta del tuboe Fissaggio dellelemento esternoComponente interno Componente internoDisegno del tubo Tubature con altre direzioni Asportazione della copertura dei fili elettrici Collegamento del cavo elettrico per interni/esterniCollegamento dei tubi Installazione del componente esternoComponente esterno ConnessioneApre ChiudeControllo dellinstallazione e test di funzionamento Tagliare il tubo Eliminare le SbavatureInserire il dado svasato Effettuare la svasatura del tubo Manuel dinstallation du climatiseur de pièce Outils nécessaires à linstallationSource dalimentation Dimensions de fixation au sol de lunité extérieure Unité mmChoix du tuyau Fixation de lunité extérieureLors de la première installation de la plaque de fixation Unité intérieureTuyauterie arrière Décharger le corps de lunité intérieure Unité intérieureFixer le corps de lunité intérieure Démontage facile pour nettoyage de lunité intérieurePuissance Branchement des tubes Installation de lunité extérieureUnité extérieure BranchementOuvrir Méthode de purge Pour utiliser unePompe à vide FermerInstallation de la source dalimentation Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China IT Conformità Alle Direttive Europee PER I ModelliES Conformidad Europea DE LAS Regulaciones Para LOS Modelos R410A GWP = Potencial de calentamiento global

HSU-07HEA03/R2, HSU-09HEA103/R2, 0010516146, HSU-22HEA03/R2 specifications

The Haier HSU series air conditioners, specifically the HSU-22HEA03/R2, HSU-09HEA103/R2, and HSU-07HEA03/R2 models, exemplify the brand's commitment to delivering efficient cooling solutions without compromising on comfort or energy consumption. These models incorporate a blend of advanced technologies and user-friendly features designed to cater to diverse climatic conditions and preferences.

One of the standout features of the HSU series is its energy-efficient design. The air conditioners boast high energy efficiency ratings, ensuring that users benefit from lower electricity bills while enjoying effective cooling. This efficiency is achieved through the implementation of inverter technology, which adjusts the compressor speed according to the cooling demand. This not only enhances performance but also significantly reduces noise levels, making for a more comfortable indoor environment.

Speaking of noise, Haier has prioritized quiet operation across the HSU series. The models are designed with sound-dampening technologies that keep operation to a minimum, allowing for a peaceful ambiance in homes and offices. This is particularly beneficial for bedrooms or shared spaces where noise can be a distraction.

The HSU series also incorporates a sophisticated air filtration system. The filters are designed to capture dust, pollen, and other airborne particles, improving indoor air quality. This feature is especially crucial for allergy sufferers and those looking to maintain a healthy living environment. Additionally, some models come equipped with a self-cleaning function, which helps to maintain the efficiency of the air conditioning unit and prolong its lifespan.

User convenience is another key characteristic of the HSU models. They come with intuitive remote controls that allow users to adjust settings such as temperature and fan speed from anywhere in the room. Furthermore, many models in the series feature programmable timers and sleep modes, ensuring optimal comfort without unnecessary energy consumption during the night.

The sleek and modern design of the HSU series units allows them to blend seamlessly into various room decors. They are compact and wall-mounted, making them suitable for both residential and commercial settings.

In summary, the Haier HSU-22HEA03/R2, HSU-09HEA103/R2, and HSU-07HEA03/R2 air conditioners are distinguished by their energy efficiency, quiet operation, advanced air filtration, and user-friendly features. With these models, Haier reinforces its reputation as a leading provider of innovative cooling solutions that prioritize comfort, efficiency, and indoor air quality.