Haier AB212XCEAA operation manual Ring terminal connection method

Page 25
Connection method for ring terminal

Installation Procedure

! Warning

!

The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire.

During wiring connection, the power cord shall be of the specified cable and reliably fastened so that external forces applied to the cable wouldnt transfer to the terminals. Improper connection or fastening will cause danger of heating, fire etc.The power cord must be fitted with a grounding wire. Grounding shall be made as specified. Unreliable grounding will cause electric shock. The grounding wire shall not be connected to the gas pipeline, water pipeline, thunder arrestor and telephone wire

! Caution

!

A current leakage breaker shall be installed, otherwise it electric shock would happen easily.

The connection method of power cord is "Y" type.

If the power cord is damaged, it must be replaced by the manufacturer or its service center or similar personnel to avoid risks. The power supply to the indoor unit shall be laid in complying with the operational instruction manual.

The electric wiring shall avoid contacting with the high temperature part of the piping so as to prevent the cable insulation melts and cause dangers.

After connected on the terminal block, the wires shall be bent to U form and then fastened with wire clip.

The control wiring and refrigerant piping may be laid and fastened together.

Before completion of vacuum pumping of the refrigerant pipe system, do not electrify the indoor unit.

The power cord of the indoor unit and connection wiring between indoor and outdoor units shall be laid out according to the operational instruction manual of the indoor unit.

The connection of the power cord shall comply with the local regulations.

The power supply wiring connection should meet the local regulation. After electric installation,power on them to do electric leakage test.

Wiring connection method : (the wiring diagram is attached inside the machine)

1) Ring terminal connection method

If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it through the ring at the connection wire end, then connect to the terminal board and fasten the screw.

2) Straight terminal connection method

If there isnt a ring at the end of the connection wire, the connection method shall be: loosen the terminal

screw, insert the connection wire end completely into the terminal board and fasten the screw. Pull the connection wire outwards slightly to confirm it is clamped tightly.

3) Clamping method of the connection wire

After wire connection is finished, the connection wire must be pressed tightly with wire clips, which shall apply to the outer sheath of the connection wire.

23

Image 25
Contents Operation & Installation Manual Contents Disposal of the old air conditioner Machine is adaptive in following situation Safety cautions Dont dismantle the outlet of the outdoor unit Introduction to Spare Parts Install air filter MaintenanceClean Open inlet grillInstall inlet grill Take off air-filter Take of inlet grill CleanInstall swing plate Close inlet grillSeasonal Reserve Post-season Care Followings are not malfuncition Trouble ShootingOFF Insufficient cooling or heating When Trouble HappensCustomer Need-to-know Customer Need-to-knowWiring Installation ProcedureLocation Operating noiseMeanings of Warning and Cautions Selection of Installation Place Before InstallationDont discard any accessories until comp Installation example Preparation for the InstallationAfter installation on the ceiling Installation of Indoor UnitCase of new ceiling Case of ceiling already existsPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage PipeWhen wiring is not complete After wiringWiring Example WiringInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Ring terminal connection method Wire connection for built-in indoor unit Remote receiver can indicate the failure code Failure codeHaier Group

AB212XCEAA specifications

The Haier AB212XCEAA is a modern refrigerator that exemplifies innovation and efficiency in kitchen appliances. Designed with the needs of contemporary households in mind, this model combines advanced technology with user-friendly features, making it a popular choice among consumers.

One of the standout features of the Haier AB212XCEAA is its large storage capacity. With a total volume that can accommodate all your groceries and perishables, it allows users to store a variety of items without the hassle of overcrowding. The flexible shelving and adjustable door bins enhance organization, enabling users to maximize space with ease.

Energy efficiency is another significant characteristic of the Haier AB212XCEAA. This refrigerator is designed to operate with minimal energy consumption, contributing to lower utility bills while being environmentally friendly. The energy-saving features are complemented by an advanced cooling system that ensures consistent temperatures throughout, preserving the freshness of food for longer periods.

The Haier AB212XCEAA also incorporates a No Frost technology. This feature eliminates the need for manual defrosting by preventing the build-up of ice within the freezer compartment. It not only minimizes maintenance but also ensures optimal airflow, enhancing the preservation of frozen items.

Interior lighting is thoughtfully designed in this model, featuring LED lights that provide clear visibility without generating excess heat. This ensures that users can easily locate their items, even in low light.

Another notable advantage is the inclusion of antibacterial technology in the refrigerator’s design. This feature helps to reduce the potential for bacterial growth, keeping food safe and extending its shelf life.

The Haier AB212XCEAA is equipped with a silent operation technology, ensuring that it runs quietly in the background — a significant advantage for households where noise can be an issue.

In summary, the Haier AB212XCEAA represents a perfect blend of style, efficiency, and cutting-edge technology. Its spacious interior, energy-saving features, No Frost technology, and quiet operation make it a top choice for modern kitchens, ensuring that your food storage needs are met with optimal performance and convenience.