Graco Sound Data, 50 1 Fire-Ball300 Pumps, 50 1 and 75 1 Fire-Ball425 Pumps

Page 15
Sound Data

Sound Data

See the pump instruction manual for technical data including wetted parts, port sizes, maximum air consumption, maximum delivery, and so on. Sound data for the pumps on these units are as follows:

50:1 Fire-Ball 300 Pumps

Tested at 100 psi (0.7 MPa, 7 bar) at 40 cycles per minute

Sound Pressure Level, measured at 1 meter from unit

77.8 dB(A)

 

 

Sound Power Level, tested in accordance with ISO 9614–2

85.6 dB(A)

 

 

50:1 and 75:1 Fire–Ball 425 Pumps

Tested at 100 psi (0.7 MPa, 7 bar) at 15 cycles per minute

Sound Pressure Level, measured at 1 meter from unit

80.9 dB(A)

 

 

Sound Power Level, tested in accordance with ISO 9614–2

94.6 dB(A)

 

 

307880 15

Image 15
Contents 307880K Instructions - Parts ListFire-BallR 300 and Grease PumpsCaution Symbol Table of ContentsSymbols Warning SymbolTOXIC FLUID HAZARD SKIN INJECTION HAZARDMOVING PARTS HAZARD FIRE AND EXPLOSION HAZARDInstallation GroundingGround all of this equipment Open Drum, Cover Mounted Pumps Typical Installation For Stationary MountingsInstalling the Hose Kit See Fig Stationary Mounting LayoutFire-Ball300 pump shown Air Line and AccessoriesInstallation GroundingSee Fig.Mounting Typical Installation For Mobile MountingsMobile Mounting Layout Drum With Hold-downKitPressure Relief Procedure OperationStart-up 307880 Description Parts Drawings and Lists50 1 Fire-Ball300, 120-lbdrum size 75 1 Fire-Ball425, 120-lbdrum sizeDescription 50 1 Fire-Ball300, 400-lbdrum sizeParts Drawings and Lists 30788075 1 Fire-Ball425, 120-lbdrum size 50 1 Fire-Ball425, 120-lbdrum sizeParts Drawings and Lists 50 1 Fire-Ball300, 120-lbdrum size307880 75 1 Fire-Ball425, 400-lbdrum sizeParts Drawings and Lists 50 1 Fire-Ball300, 400-lbdrum sizeDescription ModelParts Drawings and Lists ModelSound Data 50 1 Fire-Ball300 Pumps50 1 and 75 1 Fire-Ball425 Pumps Sales Offices Minneapolis Graco Standard WarrantyGraco Phone Numbers FOR GRACO CANADA CUSTOMERS