Typical Installation For Stationary Mountings

Installation

Note: See page 7 for the mobile mounting installation. See page 5 for hose and air accessory installation.

Typical Installation For Stationary Mountings

Key

A Fluid dispense line B Pump ground wire C Air regulator

B

C

D Main air supply line E Air filter

F Pump lubricator

G Pump runaway valve H Follow plate

A

D

G FE

H

06369B

Stationary Mounting Layout

1.Plan the layout for easy operator access to the pump air controls, sufficient room to change drums, and a secure platform.

2.For ease in changing drums, install a pump eleva- tor.

Installing the Hose Kit See Fig. 2

For pumps using Hose Kit 222072

1.Install the 3/8” swivel adapter (102) in the pump air inlet or air regulator line coupler (d) whichever is applicable. Connect the 3/8” ID air hose (101) to the swivel. Connect the air hose to the air acces- sories.

2.Connect the 1/4” swivel adapter (104) to the pump fluid outlet. Connect the 1/4” ID fluid hose (103) to the swivel. Connect a suitable dispensing valve or extra hose to the 6-ft hose.

Open Drum, Cover Mounted Pumps

Models 225014, 225016, 225781, 233108, 244635,

and 244636.

1.Remove the original drum cover.

2.Place the drum cover (3) on the drum, and fasten it with the screws and washers provided. Carefully guide the pump riser tube through the mounting gasket.

For pumps using Hose Kit 222076

1.Install the 1/2” swivel adapter (102) in the pump air inlet or air regulator line coupler (d) whichever is applicable. Connect the 1/2” ID air hose (101) to the swivel. Connect the air hose to the air acces- sories.

2.Connect the 3/8” swivel adapter (104) to the pump fluid outlet. Connect the 3/8” ID fluid hose (103) to the swivel. Connect a suitable dispensing valve or extra hose to the 6-ft hose.

307880 5

Image 5
Contents Fire-BallR 300 and Instructions - Parts ListGrease Pumps 307880KSymbols Table of ContentsWarning Symbol Caution SymbolMOVING PARTS HAZARD SKIN INJECTION HAZARDFIRE AND EXPLOSION HAZARD TOXIC FLUID HAZARDGround all of this equipment InstallationGrounding Installing the Hose Kit See Fig Typical Installation For Stationary MountingsStationary Mounting Layout Open Drum, Cover Mounted PumpsInstallation Air Line and AccessoriesGrounding Fire-Ball300 pump shownMobile Mounting Layout Typical Installation For Mobile MountingsDrum With Hold-downKit See Fig.MountingStart-up Pressure Relief ProcedureOperation 307880 50 1 Fire-Ball300, 120-lbdrum size Parts Drawings and Lists75 1 Fire-Ball425, 120-lbdrum size DescriptionParts Drawings and Lists 50 1 Fire-Ball300, 400-lbdrum size307880 DescriptionParts Drawings and Lists 50 1 Fire-Ball425, 120-lbdrum size50 1 Fire-Ball300, 120-lbdrum size 75 1 Fire-Ball425, 120-lbdrum sizeParts Drawings and Lists 75 1 Fire-Ball425, 400-lbdrum size50 1 Fire-Ball300, 400-lbdrum size 307880Parts Drawings and Lists ModelModel Description50 1 and 75 1 Fire-Ball425 Pumps Sound Data50 1 Fire-Ball300 Pumps Graco Phone Numbers Graco Standard WarrantyFOR GRACO CANADA CUSTOMERS Sales Offices Minneapolis