Graco 300, 425 Skin Injection Hazard, Moving Parts Hazard, Fire And Explosion Hazard

Page 3
SKIN INJECTION HAZARD

MOVING PARTS HAZARD WARNING

SKIN INJECTION HAZARD

Fluid from the dispense valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

D Fluid injected into the skin is a serious injury. The injury may look like just a cut, but it is a serious injury. Get immediate surgical treatment.

DDo not point the dispense valve at anyone or at any part of the body.

DDo not put your hand or fingers over the dispensing nozzle.

DDo not stop or deflect leaks with your hand, body, glove or rag.

DDo not “blow back” fluid; this is not an air spray system.

DAlways have the dispensing nozzle on the dispense valve when dispensing.

DFollow the Pressure Relief Procedure on page 8 if the tip clogs and before cleaning, checking or servicing the equipment.

DTighten all fluid connections before operating the equipment.

DCheck the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

MOVING PARTS HAZARD

Moving parts can pinch or amputate your fingers.

DKeep clear of all moving parts when starting or operating the pump.

DBefore checking or servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury.

DGround the equipment and the object being lubricated. Refer to Grounding on page 4.

DIf there is any static sparking or you feel an electric shock while using this equipment, stop dis- pensing immediately. Do not use the equipment until you identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.

DKeep the dispensing area free of debris, including solvent, rags, and gasoline.

DDo not smoke in the dispensing area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

DKnow the specific hazards of the fluid you are using.

DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

DAlways wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

307880 3

Image 3
Contents 307880K Instructions - Parts ListFire-BallR 300 and Grease PumpsCaution Symbol Table of ContentsSymbols Warning SymbolTOXIC FLUID HAZARD SKIN INJECTION HAZARDMOVING PARTS HAZARD FIRE AND EXPLOSION HAZARDInstallation GroundingGround all of this equipment Open Drum, Cover Mounted Pumps Typical Installation For Stationary MountingsInstalling the Hose Kit See Fig Stationary Mounting LayoutFire-Ball300 pump shown Air Line and AccessoriesInstallation GroundingSee Fig.Mounting Typical Installation For Mobile MountingsMobile Mounting Layout Drum With Hold-downKitPressure Relief Procedure OperationStart-up 307880 Description Parts Drawings and Lists50 1 Fire-Ball300, 120-lbdrum size 75 1 Fire-Ball425, 120-lbdrum sizeDescription 50 1 Fire-Ball300, 400-lbdrum sizeParts Drawings and Lists 30788075 1 Fire-Ball425, 120-lbdrum size 50 1 Fire-Ball425, 120-lbdrum sizeParts Drawings and Lists 50 1 Fire-Ball300, 120-lbdrum size307880 75 1 Fire-Ball425, 400-lbdrum sizeParts Drawings and Lists 50 1 Fire-Ball300, 400-lbdrum sizeDescription ModelParts Drawings and Lists ModelSound Data 50 1 Fire-Ball300 Pumps50 1 and 75 1 Fire-Ball425 Pumps Sales Offices Minneapolis Graco Standard WarrantyGraco Phone Numbers FOR GRACO CANADA CUSTOMERS