Greenheck Fan SFB, SWB, SFD manual Typical Installations, Wheel Diameters

Page 11

Typical Installations

General Clean Air or Fume Hood (Non–Grease)

The SFD, SFB and SWB are designed for applications ranging from clean air to contaminated air. Typical installations are shown below. Installations must include a means for inspecting, cleaning and servicing the exhaust fan.

Flex

Flex

3 Wheel

Diameters

SWB, Commercial Kitchen (Grease)

Greenheck’s SWB Series 200 and 300 are designed to meet restaurant and foodservice applications. These fans are UL and cUL Listed for grease removal and have been tested under elevated temperature conditions.

Due to high temperatures and grease-laden airstreams in commercial kitchen ventilation, system designers must be aware of governing codes and guidelines. The National Fire Protection Association (NFPA) is the primary source used by many local codes for commercial kitchen ventilation systems. Local code authorities should be consulted before proceeding with any kitchen ventilation project.

Upblast Discharge

Optional

Companion

Flange

**40 in.

Weatherhood

 

 

 

 

 

 

 

 

 

(1016 mm)

 

 

 

3 Wheel

 

 

 

 

 

 

 

 

Diameters

 

 

 

 

 

 

 

 

 

 

 

Installation must include a means for inspecting, cleaning and servicing the exhaust fan.

Fans selected for grease removal must include a weatherhood, access door and 1inch (25 mm) drain connection. For grease applications where the fan is mounted indoors, the welded scroll option must be selected. An outlet guard is strongly recommended when the fan discharge is accessible. When an outlet guard is not ordered with the fan, it must be provided by the installer. An upblast discharge is recommended. No dampers are to be used in

the system.

The fan discharge must be a minimum of 40 inches (1016 mm) above the roof line and the exhaust duct must be fully welded to a minimum distance of 18 inches (457 mm) above the roof surface.

SWB Series 200 and 300 models are listed for grease removal (UL/cUL 762).

File no. MH11745

*18 in.

(457 mm)

**Per NFPA 96 the fan discharge must be a minumum distance of 40 in. (1016 mm) above the roof surface.

Duct

From *Per NFPA 96 the duct must

Kitchen be all welded construction

Hood to a minumum distance of 18 in. (457 mm) above the

roof surface.

11

Image 11
Contents Centrifugal Utility Fans Utility Fans Models SFD, SFB and SWBModel Comparison Installation Standard Construction FeaturesSFD Severe Duty Options High Temperature OptionsOptions and Accessories Vibration Isolators Mounting OptionsSelection Engineering DataWheel Diameters Typical InstallationsSFD and SFB Discharge SWB Discharge Model Number Code Fan IdentificationSFD Direct Drive SFB-9 SFB-9 Belt DriveSFB-10 SFB-10 Belt DriveSFB-12 SFB-12 Belt DriveSFB-15 SFB-15 Belt DriveSFB-18 SFB-18 Belt DriveSFB-20 SFB-20 Belt DriveSFB-22 SFB-22 Belt DriveSFB-25 SFB-25 Belt DriveSFB-27 SFB-27 Belt DriveSFB-30 SFB-30 Belt DriveSWB-106 SWB-106 Belt DriveSWB-107 SWB-107 Belt DriveSWB-108 SWB-108 Belt DriveSWB-110 SWB-110 Belt DriveSWB-113 SWB-113 Belt DriveSWB-115 SWB-115 Belt DriveSWB-116 SWB-116 Belt DriveSWB-118 SWB-118 Belt DriveSWB-120 SWB-120 Belt DriveSWB-124 SWB-124 Belt DriveSWB-206 SWB-206 Belt DriveSWB-207 SWB-207 Belt DriveSWB-208 SWB-208 Belt DriveSWB-210 SWB-210 Belt DriveSWB-212 SWB-212 Belt DriveSWB-213 SWB-213 Belt DriveSWB-215 SWB-215 Belt DriveSWB-216 SWB-216 Belt DriveSWB-218 SWB-218 Belt DriveSWB-220 SWB-220 Belt DriveSWB-222 SWB-222 Belt DriveSWB-224 SWB-224 Belt DriveSWB-327 SWB-327 Belt DriveSWB-327-AF SWB-327-AF Belt DriveSWB-330 SWB-330 Belt DriveSWB-330-AF SWB-330-AF Belt DriveSWB-333 SWB-333 Belt DriveSWB-333-AF SWB-333-AF Belt DriveSWB-336 SWB-336- Belt DriveSWB-336-AF SWB-336-AF Belt DriveSWB-340 SWB-340 Belt DriveSWB-340-AF SWB-340-AF Belt DriveSWB-344 SWB-344 Belt DriveSWB-344-AF SWB-344-AF Belt DriveSWB-349 SWB-349 Belt DriveSWB-349-AF SWB-349-AF Belt DriveModel SFD Direct Drive Utility Fans PageSFD andHeaderSFB SpecificationsModel SWB Series 100, 200 and 300 Belt Drive Utility Fans SWB-SpecificationsQuiet dependable operation Other Centrifugal Fan Products

SWB, SFD, SFB specifications

Greenheck Fan’s SFB, SFD, and SWB series represent advanced solutions in ventilation technology, designed to cater to a variety of commercial and industrial applications. Each series brings unique features and optimizations that enhance airflow efficiency and reliability, making them suitable for schools, warehouses, and manufacturing facilities.

The SFB series stands out with its durable construction and high-performance capabilities. These fans are engineered for direct drive applications, offering quieter operation and lower maintenance compared to belt-driven alternatives. The SFB series features efficient backward-inclined airfoil blades, which minimize energy consumption while maximizing airflow. Additionally, they are designed with an innovative airflow path that reduces turbulence and improves overall performance.

In contrast, the SFD series is intended for applications requiring high static pressure capabilities. It incorporates a special housing design that allows for increased efficiency in high-pressure environments. The advanced motor technology in the SFD series contributes to significant energy savings, while the unit's adjustable pitch blades ensure optimal performance across various operating conditions. These fans are particularly popular in commercial kitchen exhaust systems, where effective removal of smoke and odors is critical.

The SWB series, meanwhile, is specifically designed for sidewall applications, making it a versatile option for residential and light commercial use. The SWB fans feature a compact design that facilitates easy installation in tight spaces, and their weather-resistant construction ensures reliable performance even in challenging outdoor conditions. Additionally, these fans utilize energy-efficient motor designs that further contribute to their low operational costs.

All three series prioritize user-friendly operation and maintenance. They are equipped with standard access panels that provide easy interior access for cleaning and servicing, thereby extending the lifespan of the equipment. Greenheck also emphasizes noise reduction in its designs, employing sound-dampening technologies and vibration isolation features to ensure a quieter operation.

In conclusion, Greenheck Fan’s SFB, SFD, and SWB series represent a commitment to innovation in ventilation technology. Their distinctive characteristics, including energy efficiency, durability, and ease of maintenance, make them ideal choices in a wide array of applications, from industrial to residential settings. With ongoing advancements in technology, Greenheck continues to set benchmarks in the industry, ensuring effective air movement solutions that align with modern sustainability demands.