Installation
Warning  | Handle the Interface Expander by the front panel. Do not  | |
  | touch the exposed printed circuit board or components.  | |
  | Touching the circuit board or components may result in  | |
  | damage to the Interface Expander.  | |
  | 
  | |
Reminder  | Before you install the Interface Expander, install any | |
  | required power management software (PowerChute, Power-  | |
  | Chute plus, or software required by your operating system).  | |
  | If you plan to use PowerChute plus on servers connected to  | |
  | the Basic ports of the Interface Expander, see “Master  | |
  | server versus Interface Expander servers” on page 8 and  | |
  | “Configuring PowerChute plus for simple signaling” on  | |
  | page 9.  | 
  | 
  | 
  | |
Installation  | To install the Interface Expander, perform the following  | |
procedure  | steps in the order given.  | |
  | Note: If your UPS configuration uses more than one  | |
  | SmartSlot device, refer to “Multiple SmartSlot Instal-  | |
  | lation” on page 12 before proceeding. | |
  | 1 Turn off the UPS or device that will house the  | |
  | Interface Expander. To turn off the UPS:  | |
  | a  | Unplug the UPS. | 
  | b  | Turn off the UPS output by pressing the  | 
  | 
  | Off button for at least 5 seconds.  | 
2Unpack the Interface Expander. The shipping materials are recyclable. Please reuse or dispose of them appropriately.
3Use a #2 Phillips head screwdriver to remove the two screws fastening the accessory slot cover on the back panel of the UPS or device. Keep the screws for Step 5 below. Save the accessory slot cover for future use (e.g., shipping the UPS).
Continued on next page
15