Greenheck Fan ERVe Optional Accessories Checklist, Economizer Application / Operation section

Page 20

Optional Accessories Checklist

Refer to the respective sections in this Installation, Operation and Maintenance Manual for detailed information. Refer to wiring diagram in unit control center to determine what electrical accessories were provided.

Provided with Unit?

Frost Control Application / Operation section:

Setting

Factory Default

 

 

 

 

 

Yes

No

Frost Control set point

 

5ºF

 

 

 

 

 

 

 

Differential

 

2ºF

 

 

Timer

 

Refer to IOM

 

 

 

 

 

Yes

No

Frost Control Modulating

 

Refer to IOM

 

 

 

 

 

Economizer Application / Operation section:

 

 

 

 

 

 

 

Yes

No

Economizer (temperature)

 

 

 

 

 

 

 

 

 

Set point

 

65ºF

 

 

 

 

 

 

 

Offset

 

20ºF

 

 

 

 

 

 

 

Differential

 

2ºF

 

 

 

 

 

Yes

No

Economizer (enthalpy)

 

 

 

 

 

 

 

 

 

Set point

 

D

 

 

 

 

 

Yes

No

Economizer (modulating)

 

Refer to IOM

 

 

 

 

 

Optional Accessories section:

 

Operational

 

 

 

 

 

 

 

Yes

No

Wheel Rotation Sensor

Yes

No

N/A

 

 

 

 

 

 

Yes

No

OA Dirty Filter Sensor

Yes

No

N/A

 

 

 

 

 

 

Yes

No

EA Dirty Filter Sensor

Yes

No

N/A

 

 

 

 

 

 

Yes

No

CO2 Sensor

Yes

No

N/A

Yes

No

Service Outlet

Yes

No

N/A

 

 

 

 

 

 

Yes

No

Vapor Tight Lights

Yes

No

N/A

 

 

 

 

 

 

Yes

No

Remote Control Panel

Yes

No

N/A

 

 

 

 

 

 

Variable Frequency Drives section:

 

Operational

 

 

 

 

 

 

 

Yes

No

Blower VFDs

Yes

No

N/A

 

 

 

 

 

 

Yes

No

Wheel VFD

Yes

No

N/A

 

 

 

 

 

 

Damper section:

 

 

Operational

 

 

 

 

 

 

 

Yes

No

Outdoor Air Damper

Yes

No

N/A

 

 

 

 

 

 

Yes

No

Exhaust Air Damper

Yes

No

N/A

 

 

 

 

 

 

20 Model ERVe Energy Recovery Unit

Image 20
Contents Installation, Operation and Maintenance Manual Model ERVe General Safety InformationInspection and Maintenance during Storage ReceivingUnpacking HandlingTable of Contents Supplemental Installation Operation and Maintenance ManualsInstallation Basic OperationRoof Curb and Rail Mounting Lifting with a CraneLifting with a Forklift Recommended Roof OpeningDuctwork Connections Curb Outside Dimensions and WeightsRoof Curb Mounting Rail Mounting / Layout Service ClearancesAccess Panel Description and Location Dimensional Data Duct Dimensions Unit SizeElectrical Information Typical Control Center Components Electric Heater Application/OperationUnit Accessories Outdoor Air WeatherhoodExhaust Weatherhood DampersOptional Accessories Frost Control Application/OperationTesting Temperature Sensor with Override Economizer Application/OperationModulating the Wheel Enthalpy Sensor with OverrideDrive Operation Variable Frequency Drives for Energy Recovery BlowersFactory Set Points 10 VDC Variable Frequency Drives for Energy Recovery WheelEconomizer Signal Source Typical Wiring Diagram TransformerService Outlet Rotation SensorDirty Filter Sensor CO2 SensorRemote Control Panel and Wiring Schematics Indicator Lights powered by the ER UnitDay Timer or On/Off Switch Dirty Filter Indicator power by othersTemperature Sensors 1K Ohm RTD Sensors Mounted by FactoryPressure Sensors analog or digital Amp Current Sensors analog or digitalPre Start-Up Checklist check as items are Start-Up ChecklistStart-Up General Start-Up InformationOptional Accessories Checklist Optional Accessories sectionEconomizer Application / Operation section Variable Frequency Drives sectionUnit Start-Up Energy Recovery Wheel VibrationDrive Belt Air SealsRoutine Maintenance Maintenance Procedures LubricationFan Belts Fan MotorsExternal Filter Maintenance Internal Filter MaintenanceDoor Seal Maintenance Fan Wheel & FastenersEnergy Recovery Wheel Maintenance Parts List Sequence of OperationTroubleshooting Airflow Troubleshooting Unit Symptom Possible Cause Corrective ActionTroubleshooting Unit Maintenance Log Model ERVe Energy Recovery Unit Warranty

ERVe specifications

The Greenheck Fan ERVe series stands at the forefront of energy-efficient ventilation solutions, specifically designed to meet the growing demands for energy conservation and enhanced indoor air quality in commercial buildings. As part of Greenheck's commitment to innovation, the ERVe series offers a variety of models tailored to diverse applications, including schools, hospitals, and office buildings.

One of the key features of the ERVe series is its advanced energy recovery technology. The ERVe utilizes a heat recovery wheel that efficiently transfers heat and moisture between the exhaust and incoming airstreams. This process significantly reduces heating and cooling loads on HVAC systems, promoting energy savings and improving overall system efficiency. By reclaiming energy that would otherwise be wasted, the ERVe ensures that buildings not only conform to energy codes but also contribute to sustainability goals.

The ERVe series is designed with versatility in mind. It offers multiple configurations, including vertical and horizontal orientations, which makes it adaptable to various installation environments. Additionally, the unit can be equipped with a range of options such as pre-filters, post-filters, and variable speed drive motors, allowing for customization based on specific application needs. This adaptability ensures that the ERVe can meet the specific air quality requirements of different spaces while maintaining optimal airflow.

Another significant characteristic of the ERVe series is its low noise operation. The design incorporates advanced acoustical features, including sound attenuators and insulated panels, which minimize sound transmission and enhance occupant comfort. As noise control becomes increasingly important in settings like educational institutions and healthcare facilities, the ERVe series excels in providing a peaceful indoor environment.

Moreover, the ERVe series is engineered with durability in mind. Constructed from high-quality materials, the units are built to withstand the rigors of continuous operation. The robust design not only extends the service life of the equipment but also reduces maintenance requirements, leading to lower overall operational costs.

In terms of control and monitoring, the ERVe series is compatible with various building management systems, allowing for integration into sophisticated HVAC controls. This feature enables real-time data tracking and optimization, enhancing the efficiency of indoor climate management.

Overall, the Greenheck Fan ERVe series represents a significant advancement in ventilation technology, combining energy efficiency, customizable features, low noise operation, and durability. These characteristics ensure that the ERVe is a reliable choice for modern commercial buildings striving for improved air quality and reduced energy consumption.