Genelec 1030A Operating Manual, System Specifications Crossover Section Amplifier Section

Page 4

1030A Operating Manual

AUDIO PRECISION 1030anec LEVEL(dBr) vs FREQ(Hz)14 JAN 94 12:34:40

100

 

95

0

 

90

15

 

AUDIO PRECISION 1030anec LEVEL(dBr) vs FREQ(Hz)

14 JAN 94 12:09:56

100

 

95

TREBLE TILT

90

BASS TILT

85

80

75

70

30

45

85

80

75

BASS ROLL-OFF

70

65100

6095

5590

20

100

1k

10k

20k

Figure 4. The upper curve group shows the horizontal directivity

characteristics of the 1030A in vertical configuration measured at 1 m.

The lower curve is a 1/3 octave band power response, measured in an IEC approved reverberation chamber.

65

60

55

50

20

100

1k

10k

20k

Figure 5. The curves show the effect of the bass tilt, treble tilt and bass roll-off controls on the free field response.

SYSTEM SPECIFICATIONS

CROSSOVER SECTION

AMPLIFIER SECTION

Lower cut-off frequency, -3 dB:

< 52 Hz

Upper cut-off frequency, -3 dB:

> 20 kHz

Free field frequency response of system: 55 Hz - 18 kHz (± 2.5 dB)

Maximum short term sine wave acoustic output on axis in half space, averaged from 100 Hz to 3 kHz:

@1m > 105 dB SPL

@0.5m > 111 dB SPL

Maximum long term RMS acoustic output in same conditions with IEC weighted noise (limited by driver unit protection circuit):

@1m > 99 dB SPL

@0.5m > 105 dB SPL

Maximum peak acoustic output per pair above console top, @ 1 m from the engineer with music

material:

> 115 dB

Self generated noise level in free field @ 1m

on axis: < 10 dB (A-weighted)

Harmonic distortion at 90 dB SPL @ 1m on axis:

Freq:

60...150 Hz

< 3%

 

> 150 Hz

< 0.5%

Drivers: Bass 170 mm (6 1/2") cone Treble 19 mm (3/4") metal dome

Both drivers are magnetically shielded.

Weight:

7,6 kg (17 lb)

Dimensions:

 

 

 

Height 312 mm (12 1/4")

 

Width

200 mm ( 7 7/8")

 

Depth

240 mm (9 7/16")

Input connector XLR female:

pin 1 gnd pin 2 + pin 3 -

Input impedance:

10 kOhm balanced

Input level for 100 dB SPL output @ 1m: variable from +6 to -6 dBu

Input level for maximum short term sine wave output of 105 dB SPL @ 1m:

variable from +11 to -1 dBu

Subsonic filter below 50 Hz :

18 dB/octave

Ultrasonic filter above 25 kHz:

12 dB/octave

Crossover frequency, Bass/Treble:

3.5 kHz

Crossover acoustical slopes:

24 - 32 dB/octave

Treble tilt control operating range in 2 dB steps: from +2 to -4 dB & MUTE

Bass roll-off control operating range in 2 dB steps: from 0 to -8 dB @ 50 Hz

Bass tilt control operating range in 2 dB steps: from 0 to -6 dB @ 100 Hz & MUTE

The 'CAL' position is with all tone controls set to 'off' and the input sensitivity control to maximum (fully clockwise).

Bass amplifier short term output power with a

4 Ohm load:

80 W

Treble amplifier short term output power with an

8 Ohm load:

50 W

Long term output power is limited by driver unit protection circuitry.

Amplifier system distortion at

 

nominal output:

 

 

 

THD

< 0.08%

 

SMPTE-IM

< 0.08%

 

CCIF-IM

< 0.08%

 

DIM 100

< 0.08%

Signal to Noise ratio, referred to full output:

 

Bass

> 95 dB

 

Treble

> 95 dB

Mains voltage:

230, 100/200 or 115/230V

 

according to region

Voltage operating range:

±10%

Power consumption:

 

 

 

Idle

10 VA

 

Full output

100 VA

Genelec Document D1030AR001 Copyright Genelec Oy 3.2003. All data subject to change without prior notice

International enquiries:

Genelec, Olvitie 5

FIN-74100, Iisalmi, Finland

Phone +358 17 83881

Fax +358 17 812 267

Email genelec@genelec.com

 

www.genelec.com

In the U.S. please contact:

In China please contact:

Genelec, Inc., 7 Tech Circle

Genelec China Representative Office

Natick, MA 01760, USA

Soho New Town, 88 Jianguo Road

Phone +1 508 652 0900

D-1504, Chaoyang District

Fax +1 508 652 0909

Beijing 100022, China

Email genelec.usa@genelec.com

Phone +86 10 8580 2180

 

Fax +86 10 8580 2181

Image 4
Contents Genelec 1030A Operating ManualMonitoring Speaker Genelec 1030A Monitoring Speaker Setting tone controls MaintenanceSafety considerations AccessoriesSystem Specifications Crossover Section Amplifier Section 1030A Operating Manual