Goodman Mfg R-410A service manual Do not connect or use any device

Page 3

PRODUCT IDENTIFICATION

The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.

GPC1424H41A*

GPC1430H41A*

GPC1436H41A*

GPC1442H41A*

GPC1448H41A*

GPC1460H41A*

Models qualify for the 2009 and 2010 Federal Tax Credits

for Energy Efficiency**

**Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits.

WARNING

The United States Environmental Protection Agency (“EPA”) has issued various regulations re-

garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow

 

these regulations may harm the environment and can lead to the imposition of substantial fines.

 

These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.

 

 

WARNING

Do not connect or use any device

that is not design certified by

 

Goodman for use with this unit.

Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.

WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or

other flammable liquids or vapors in the vicinity of this appliance.

3

Image 3
Contents Technical Manual Product Identification Goodman will not be responsibleFor any injury or property damage Do not connect or use any device Product Design Outside Slab Installation Horizontal HRooftop Installation Horizontal H At 208 Minimum Circuit MaximumOvercurrent Ampacity Protection ampsGPC1424-60H41A Product DimensionsGPC1424H41 GPC1430H41 GPC1436H41 Package Cooling SpecificationsGPC1442H41 GPC1448H41 GPC1460H41 Package Cooling SpecificationsAccessories GPC/GPH****H Units AccessoriesDry Coil Data Blower Performance DataFormulas Performance DataCooling Performance Data GPC1424H41A105 115 151 Expanded Performance DataAirflow GPC1430H41A10.5 10.8 11.2 GPC1436H41A Is Ahri Rating Conditions 145GPC1442H41A 148 GPC1448H41A 149 GPC1460H41A 146 Performance Test GPC1424-60H41A Wiring Diagrams
Related manuals
Manual 47 pages 31.4 Kb

R-410A specifications

Goodman Manufacturing, a well-respected name in the HVAC industry, has made significant advancements with their R-410A refrigerant technology. R-410A, a hydrofluorocarbon (HFC), has positioned itself as a superior alternative to the older R-22 refrigerant, which has been phased out due to its ozone-depleting properties. Goodman’s commitment to energy efficiency and environmental sustainability is well reflected in their use of R-410A in their air conditioning and heat pump systems.

One of the main features of Goodman’s R-410A systems is their exceptional energy efficiency. The R-410A refrigerant operates at a higher pressure than R-22, which allows for better heat transfer and improved cooling capacity. This results in reduced energy consumption and lower utility bills for consumers. Goodman’s air conditioning units designed for use with R-410A are often rated with high Seasonal Energy Efficiency Ratio (SEER) ratings, making them an eco-friendly choice for residential and commercial applications.

Another notable technology employed by Goodman is their commitment to reliable performance through advanced compressor designs. Goodman's scroll compressors are optimized for R-410A, ensuring quieter operation and reducing vibration levels. These compressors are known for their efficiency and longevity, making them a favorite among homeowners seeking dependable and durable climate control solutions.

Goodman's multi-stage cooling systems that utilize R-410A offer precise temperature control and enhanced comfort. By controlling the speed of the compressor, Goodman’s units can adjust output according to the heating or cooling demand, maximizing comfort while minimizing energy waste. This adaptability not only enhances indoor air quality but also contributes to a greener environment by using less energy.

Furthermore, Goodman incorporates high-tech diagnostic controls into their systems. These controls provide real-time performance data, allowing homeowners and technicians to monitor system status and troubleshoot issues more easily. By using R-410A combined with these innovative technologies, Goodman emphasizes reliability and user-friendly operation.

In conclusion, Goodman Manufacturing’s use of R-410A refrigerant reflects their dedication to efficiency, reliability, and environmental stewardship in HVAC solutions. The combination of advanced compressor technologies, high energy efficiency, and innovative controls solidifies Goodman’s reputation as a leader in the industry, offering homeowners and businesses the comfort and peace of mind they deserve.