| Product Specifications | |
Product Specifications — 20 Tons |
|
|
|
|
|
|
|
|
|
| CPG240 | CPG240 | CPG240 |
|
| 4003B*** | 4004B*** | 4007B*** |
|
|
|
|
|
|
Cooling Capacity |
|
|
|
|
Total, BTU/h | 240,000 | 240,000 | 240,000 |
|
Sensible BTU/h | 170,000 | 170,000 | 170,000 |
|
EER / IEER | 9.8 / 10.0 | 9.8 / 10.0 | 9.8 / 10.0 |
|
Decibels | 88.3 | 88.3 | 88.3 |
|
AHRI Reference #s | 3897346 | 3897346 | 3897346 |
|
Heating Capacity |
|
|
|
|
Max. Input High / Low (KBTU/h) | 400 / 300 | 400 / 300 | 400 / 300 |
|
Output BTU/h | 320 / 240 | 320 / 240 | 320 / 240 |
|
Steady State Efficiency (%) | 80 | 80 | 80 |
|
Temperature Rise Range (°F) High/Low |
| |||
No. of Burners | 8 | 8 | 8 |
|
Evaporator Motor / Coil |
|
|
|
|
Motor Type (Belt Drive) | Std Static Belt Drive | Std Static Belt Drive | Std Static Belt Drive |
|
Indoor Nominal CFM | 7,000 | 7,000 | 7,000 |
|
Indoor Motor FLA (Cooling) | 12.7 | 6.4 | 5.1 |
|
Horsepower - RPM | 5.0 - 1,725 | 5.0 - 1,725 | 5.0 - 1,725 |
|
Metering Device | TXV | TXV | TXV |
|
Filter Size (#) | 25 x 25 x 2 (6) | 25 x 25 x 2 (6) | 25 x 25 x 2 (6) |
|
Drain Size (NPT) | 1" | 1" | 1" |
|
320 oz. | 320 oz. | 320 oz. |
| |
Evaporator Coil Face Area (ft²) | 20 | 20 | 20 |
|
Rows Deep / Fins per Inch | 4 / 16 | 4 / 16 | 4 / 16 |
|
Belt Drive Evap Fan Data |
|
|
|
|
# of Wheels (D x W) | 2 (15" x 15") | 2 (15" x 15") | 2 (15" x 15") |
|
Motor Sheave | 1VP60 x 1⅛" | 1VP60 x 1⅛" | 1VP60 x 1⅛" |
|
Blower Sheave / Belt | BK100 x 1⁷/₁₆" / BX46 | BK100 x 1⁷/₁₆" / BX46 | BK100 x 1⁷/₁₆" / BX46 |
|
Condenser Fan / Coil |
|
|
|
|
Quantity of Condenser Fan Motors | 3 | 3 | 3 |
|
Horsepower - RPM | ⅓ - 1,075 | ⅓ - 1,075 | ⅓ - 1,075 |
|
Fan Diameter / # Fan Blades | 22 / 3 | 22 / 3 | 22 / 3 |
|
Outdoor Nominal CFM | 7,200 | 7,200 | 7,200 |
|
Face Area (ft²) | 53.3 | 53.3 | 53.3 |
|
Rows Deep / Fins per Inch | 2 / 18 | 2 / 18 | 2 / 18 |
|
Compressor |
|
|
|
|
Quantity / Type | 2 / Scroll | 2 / Scroll | 2 / Scroll |
|
Compressor RLA / LRA ea. | 33.3 / 239 | 17.9 / 125 | 12.8 / 80 |
|
Electrical Data / Static |
|
|
|
|
Voltage / Phase / Frequency | 460/3/60 | 575/3/60 |
| |
Standard Max Static | 1.4 | 1.4 | 1.4 |
|
Outdoor Fan FLA / LRA | 2.4 / 5.2 | 1.2 / 2.6 | .9 / 2.2 |
|
Total Unit Amps | 86.5 | 45.8 | 33.4 |
|
Min. Circuit Ampacity¹ | 95 | 50 | 37 |
|
Max. Overcurrent Protection (amps)² | 125 | 60 | 45 |
|
Entrance Power Supply | 2⅛" | 2⅛" | 2⅛" |
|
Entrance Control Voltage | ⅞" | ⅞" | ⅞" |
|
Operating Weight (lbs) | 2275 | 2275 | 2275 |
|
Ship Weight (lbs) | 2390 | 2390 | 2390 |
|
¹Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or
Note: Always check the S&R plate for electrical data on the unit being installed.
www.goodmanmfg.com | 5 |