Goodman Mfg ARPF, ARPT, AEPT operating instructions Unit Inspection, Electric Heat, Cfm

Page 4

When matched with a Goodman or Amana brand condenser or heat pump, an ARI certified rating is available for many combinations.

The AEPT models are equipped with an ECMTM motor. An ECMTM motor is more efficient than a standard PSC motor and offers features such as soft-start, controlled off-delays, and constant CFM. Additional features and the associated controls are discussed later in this manual.

Electric heat is available for all models. This is an accessory and is not provided with the equipment. Use only the electric heat kits identified in the “Electric Heat” section of this manual.

These air handlers are intended for use with a room thermostat. This thermostat is not supplied with this equipment. Only thermostats that use 24 VAC operating voltage can be used.

UNIT INSPECTION

Upon delivery, inspect the unit for damage. Any damage must be reported immediately to the carrier. Do not install this equipment if it is determined that the integrity or safety has been compromised by freight damage.

Using the table “Model Identification” section, check the equipment model number to ensure the unit is appropriately sized for the condenser unit.

If an incorrect unit is supplied, it must not be installed and it is to be returned to the supplier. The manufacturer assumes no responsibility for the installation of incorrectly delivered units.

The evaporator coil contains a high-pressure inert gas holding charge.

ELECTRIC HEAT

WARNING

REFER TO THE “INSTALLING ELECTRIC HEAT” SECTION OF THIS MANUAL AND THE INSTRUCTIONS PROVIDED WITH THE HEAT KIT FOR THE CORRECT INSTALLATION PROCEDURE.

WARNING

THE ELECTRICAL CHARACTERISTICS OF THE AIR HANDLER, THE ELECTRIC HEAT KIT, AND THE SUPPLY POWER MUST AGREE, UNLESS USING HKR3 (3 PHASE) SERIES HEAT KIT. THIS AIR HANDLER DOES NOT HAVE FACTORY INSTALLED ELECTRIC HEAT. ELECTRIC HEAT IS AVAILABLE AS AN ACCESSORY. IF INSTALLING THIS OPTION, THE ONLY HEAT KITS THAT CAN BE USED ARE THE HKR SERIES AS INDICATED BELOW: NOTE: THE AMANA BRAND EHK, ECB, EDB, AND EDK KITS ARE NOT APPROVED FOR USE WITH THESE AIR HANDLERS.

The heating mode temperature rise is dependent upon the system airflow, the supply voltage, and the heat kit size (kW) selected. Use Tables 1-3to determine the temperature rise (oF).

CFM

 

 

HEAT KIT NOMINAL kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

5

 

6

 

8

 

10

15

 

20

21

 

 

 

 

 

 

 

 

 

 

 

 

 

600

18

28

 

35

 

41

 

 

 

 

 

 

800

13

21

 

26

 

31

 

42

 

 

 

 

1000

11

17

 

21

 

25

 

34

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

9

14

 

18

 

21

 

28

42

 

56

62

1400

8

12

 

15

 

18

 

24

36

 

48

53

1600

7

10

 

13

 

15

 

21

31

 

42

46

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

6

9

 

12

 

14

 

19

28

 

37

41

2000

5

8

 

11

 

12

 

17

25

 

34

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1

 

 

 

 

 

230/1/60 Supply Voltage - Temperature Rise Table °F

CFM

 

 

HEAT KIT NOMINAL kW

 

 

3

5

6

 

8

 

10

15

 

20

21

 

 

 

 

600

17

27

34

 

39

 

 

 

 

 

 

800

13

20

25

 

30

 

40

 

 

 

 

1000

10

16

20

 

24

 

32

48

 

 

 

1200

8

13

17

 

20

 

27

40

 

53

59

1400

7

11

14

 

17

 

23

34

 

46

51

1600

6

10

13

 

15

 

20

30

 

40

44

1800

6

9

11

 

13

 

18

27

 

36

39

2000

5

8

10

 

12

 

16

24

 

32

35

 

 

 

 

Table 2

 

 

 

 

 

220/1/60 Supply Voltage - Temperature Rise Table °F

CFM

 

 

HEAT KIT NOMINAL kW

 

 

3

5

6

 

8

 

10

15

 

20

21

 

 

 

 

600

16

25

32

 

37

 

 

 

 

 

 

800

12

19

24

 

38

 

38

 

 

 

 

1000

10

15

19

 

22

 

30

46

 

 

 

1200

8

13

16

 

19

 

25

38

 

51

56

1400

7

11

14

 

16

 

22

33

 

43

48

1600

6

9

12

 

14

 

19

28

 

38

42

1800

5

8

11

 

12

 

17

25

 

34

37

2000

5

8

10

 

11

 

15

23

 

30

34

 

 

 

 

Table 3

 

 

 

 

 

208/1/60 Supply Voltage - Temperature Rise Table °F

Note: For installations not indicated above the following formula is to be used:

TR = (kW x 3412) x (Voltage Correction) x 1.08 / CFM

Where: TR

= Temperature Rise

KW

= Heater Kit Actual kW

3412

= Btu per kW

 

Voltage Correction

=.96 (230 Supply Volts)

 

 

=.92 (220 Supply Volts)

1.08

= Constant

=.87 (208 Supply Volts)

 

CFM

= Measured Airflow

NOTE: The Temperature Rise Tables can also be used to determine the air handler airflow delivery. When using these tables for this purpose set the room thermostat to

IO-230F

4

08/04

 

 

Image 4
Contents Installation & Operating Instructions for Before Beginning Installation Replacement PartsIntroduction Checking Product ReceivedModel Identification Product DescriptionElectric Heat Unit InspectionCFM HKR Installation Electrical Supply Wire and MOPLocation DuctworkUSE Copper Conductors only Refrigerant LinesEvaporator Coil Metering Devices Piping SizeTXV Models Arpt and Aept Aept Motor Orientation Aept Motor OrientationConversion to Downflow ARUFor Arpt Aept model Insulation KitConversion to Horizontal Condensate RemovalAchieving 2% LOW Leakage Rate ARUF/ARPF MotorAept Motor Electric Heat CFMHumidity Control Thermostat WiringTwo Stage Heating RED Regular Maintenance START-UP ProcedureThermostats

AEPT, ARPF, ARPT specifications

Goodman Manufacturing is a leading name in the air conditioning and heating industry, known for its commitment to high-quality products and innovative technologies. Among its esteemed lineup are the AEPT, ARPT, and ARPF series of heat pumps, which have garnered attention for their efficiency, reliability, and advanced features.

The Goodman AEPT series is designed for high efficiency and performance. These heat pumps utilize scroll compressor technology, which not only enhances their energy efficiency but also provides quieter operation compared to traditional compressors. With a SEER (Seasonal Energy Efficiency Ratio) rating that often exceeds 15, the AEPT series allows homeowners to significantly reduce their energy costs while enjoying optimal comfort throughout the year. Additionally, these units come equipped with a weather-resistant cabinet designed to withstand harsh outdoor conditions, ensuring durability and longevity.

The ARPT series takes innovation a step further by incorporating advanced refrigerant technology. Using R-410A refrigerant, these heat pumps operate with minimal environmental impact while providing robust heating and cooling capabilities. The ARPT units are equipped with a multi-speed ECM (Electronically Commutated Motor) blower motor that allows for improved airflow and enhanced humidity control, leading to a more comfortable indoor environment. The smart design of the ARPT series also emphasizes ease of installation and service, making it a preferred choice among HVAC professionals.

Finally, the Goodman ARPF series is engineered for versatility and performance in various climates. With a focus on user-friendly features, these heat pumps are designed to operate efficiently in both heating and cooling modes. The ARPF models come with digital thermostats that provide precise temperature control, ensuring that homes remain comfortable regardless of external weather conditions. Moreover, their advanced defrost controls allow for enhanced performance in colder climates, ensuring that homeowners can rely on their heat pumps even during extreme temperatures.

In summary, the Goodman AEPT, ARPT, and ARPF heat pump series showcase cutting-edge technology and innovative features focused on energy efficiency, environmental responsibility, and user comfort. These units not only promise durability and high performance but also ease of installation and maintenance, making them a smart investment for homeowners seeking reliable climate control solutions.