Oakleaf Woodburning Stove

CLEARANCE TO COMBUSTIBLES: Corner Installation, Vertical Vent

 

Location

 

A

Shield Corner to Wall

14" / 356 mm

B

Vent Pipe to Wall

21.75" / 552 mm

Pipe clearance may be reduced using double wall or insulat- ed connector pipe, provided that you adhere to the specified clearances from the stove itself. Follow pipe manufacturer's guidelines.

B

 

B

 

 

 

A

A

B

 

 

A

CLEARANCE TO COMBUSTIBLES: Corner Installation

 

Vertical Vent, Horizontal Exit

 

 

 

Location

 

 

A

Shield Corner to Wall

14" / 356 mm

 

B

Vent Pipe to Wall

21.75" / 552 mm

*For clearance reduction methods, refer to NFPA 211 or Local Codes

CLEARANCE TO COMBUSTIBLES: Horizontal Venting Configuration

Location

AUnit to Side Wall

B Unit to Back Wall

C Vent Pipe to Side Wall

17" / 432 mm 13" / 330 mm 26.5" / 673 mm

 

Corner Installation

 

D

Shield Corner to Wall

14" / 356 mm

E

NFPA 211 specifies clearance of

18" / 457 mm

(Although vent clearance may be reduced using double-wall pipe, D must be followed)

NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place of the existing shield.

 

C

 

 

 

A

B

 

 

 

 

 

 

D

E

Save These Instructions

3-90-798

Dry Seasoned Wood Only!

11

Page 11