Chimneys and Venting

Oakleaf Woodburning Stove

5

 

 

The Chimney Connector Shall Not Pass Through an

Chimneys and Venting

 

Attic or Roof Space, Closet or Similar Concealed Space,

 

a Floor or Ceiling.

 

 

A. Draft

 

Assemble the connector beginning at the flue collar,

Draft is widely misunderstood. It is important that

with the crimped ends pointing towards the stove (to

you, the stove operator, realize that draft is a variable

keep debris or residue inside the system). Each joint,

effect, not a given quantity. Stoves and chimneys

including the one to the stove’s flue collar and the one

to the chimney itself should be secured with at least

do not have draft, yet draft is the key to your stove’s

three sheet metal screws. Screws may be a maximum

performance.

 

 

of 3 inches apart. A 1-1/4" (30 mm) overlap is required

Draft is a force, produced by an operating stove

at each joint, including the flue collar attachment. No

and the chimney to which it is attached. It is created by

more than two 90 degree elbows should be used, and

hot gases rising up the chimney, creating a pressure

the total length of connector should not exceed 10 feet

difference between the inside of your home and the

(3 m). All horizontal runs of connector must have a

outside air. It continually moves fresh combustion air

minimum upward slope of 1/4"(6 mm) per foot (20 mm

into the stove, and hot exhaust gases out of the stove;

per meter).

 

 

without this constant flow, the fire will go out.

 

The chimney connector diameter should correspond

Other factors, such as barometric pressure,

to the size of the flue collar opening. Do not use

winds, the airtightness of the home, the total inside

makeshift compromises. No part of the chimney

connector may pass through an attic or roof cemented

chimney volume, chimney height and the presence

in place with refractory cement.

 

 

of venting devices such as exhaust fans also play a

 

 

C. Wall Pass-thrus

 

 

role in maintaining an adequate draft. Low barometric

 

 

pressures, super insulated homes and exhaust fans can

Depending on your local building codes, and the

reduce draft; winds can play havoc with draft; and too

pertinent provincial or national codes, there are several

large or too small a chimney volume can cause reduced

choices for passing the chimney connector safely

draft due to the excessive cooling or not enough room

through a wall. Before beginning your installation,

to vent exhaust gases. Introducing outside air

directly

contact local officials, and also the chimney connector

to the stove may help remedy a low draft problem.

and chimney manufacturer for specific requirements.

Some signs of inadequate draft are smoking, odor,

Canada. Three methods are approved by the

difficulty in maintaining the fire, and low heat output.

Canadian Standards Association. The diagram on the

Overdraft can be caused by a very tall chimney even if

next page shows one method requiring an 18"(450 mm)

it is the recommended size, and can cause overfiring

air space between the connector and the wall. It allows

of your stove. Signs of an overdraft include rapid fuel

use of one or two covers as described in the diagram.

consumption, inability to slow the fire, and parts of the

The two other methods are described in detail in the

stove or chimney connector glowing red. It is important

current issue of CAN/CSA B365, the national standard.

that you follow the chimney guidelines in this manual,

United States In the U.S., the national code is NFPA

including size, type, and height to avoid draft problems.

211. While many localities adopt this standard, be sure

When installed and operated according to this

to check with local authorities before beginning your

manual, the Oakleaf will produce enough hot gases

to keep the chimney warm so that adequate draft is

installation.

 

 

maintained throughout the burn cycle.

 

The NFPA (National Fire Protection Agency) permits

B. Chimney Connectors

 

four methods for passing through a combustible wall. A

In general, following these guidelines will ensure

commonly used method to pass through a wall directly

compliance with all national and provincial codes;

to a masonry chimney is to clear a minimum 12"(300

prior to beginning your installation, check with your

mm) around the entire chimney connector, and fill it

local building code official to check on additional

with brick masonry which is at least 3.5"(90 mm) thick.

local regulations which may influence the design and

A fireclay liner, minimum 3/8" (9 mm) wall thickness

placement of your venting system.

 

must run through the brick wall to the chimney liner (but

The Harman Oakleaf may be installed with a minimum

not beyond the inner surface of the liner). It must be

(.6 mm) 24 gauge chimney connector pipe. The size of

cemented in place with refractory cement. This method

the connector should correspond to the size of the flue

collar opening. Do not use makeshift compromises. No

is illustrated on the next page. For details on the other

part of the chimney connector may pass through an

three options, refer to the most recent edition of the

attic or roof space, closet or other concealed space,

NFPA 211 code.

 

 

or through a floor or ceiling. Whenever possible, avoid

 

 

 

passing the connector through a combustible wall; if you

 

 

 

must, use an approved wall pass-through, described

 

 

 

later in this section.

 

 

 

 

 

 

 

 

 

 

Save These Instructions

3-90-798

Dry Seasoned Wood Only!

13

 