Goodman Mfg AEPT, ARPT Introduction, Checking Product Received, Before Beginning Installation

Page 2

INDEX

 

INTRODUCTION

2

REPLACEMENT PARTS

2

SAFETY INSTRUCTIONS

2

WARNINGS

2

MODEL IDENTIFICATION

3

PRODUCT DESCRIPTION

3

UNIT INSPECTION

4

ELECTRIC HEAT

4

HKR INSTALLATION

5

LOCATION

5

DUCTWORK

5

ELECTRICAL SUPPLY WIRE AND MOP

5

REFRIGERANT LINES

6

AEPT MOTOR ORIENTATION

8

CONVERSION TO DOWNFLOW

8

CONVERSION TO HORIZONTAL

9

CONDENSATE REMOVAL

9

ACHIEVING 2% LOW LEAKAGE RATE

10

ARUF/ARPF MOTOR

10

AEPT MOTOR

10

THERMOSTAT WIRING DIAGRAMS

11

THERMOSTATS

13

INTRODUCTION

Checking Product Received

Upon receiving the product, inspect it for damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. Check the product to determine if it is correct. In the event an incorrect product is shipped, it must be returned to the supplier and must NOT be installed. The manufacturer assumes no responsibility for installation of incorrectly shipped products.

Before Beginning Installation

Carefully read all instructions for the installation prior to installing product. Make sure each step or procedure is understood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally. Make sure everything needed to install the product is on hand before starting.

REPLACEMENT PARTS

Ordering Parts

When reporting shortages or damages, or ordering repair parts, give the complete product model and serial numbers as stamped on the product. Replacement parts for this product are available through your contractor or local distributor. For the location of your nearest distributor consult the white business pages, the yellow page section of the local telephone book, or contact the following:

SERVICE PARTS DEPARTMENT

GOODMAN MANUFACTURING COMPANY, L.P.

2550 NORTH LOOP WEST, SUITE 400

HOUSTON, TEXAS 77092

(713) 861 – 2500

IMPORTANT SAFETY INSTRUCTIONS Recognize Safety Symbols, Words, and Labels

The following symbols and labels are used throughout this manual to indicate immediate or potential hazards. It is the owner’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of serious personal injury or death, property damage and/or product damage.

DANGER

IMMEDIATE HAZARDS WHICH WILL RESULT IN PROPERTY DAMAGE, PRODUCT DAMAGE, SEVERE PERSONAL INJURY OR DEATH.

WARNING

HAZARDS OR UNSAFE PRACTICES COULD RESULT IN PROPERTY DAMAGE, PRODUCT DAMAGE, SEVERE PERSONAL INJURY OR DEATH.

CAUTION

HAZARDS OR UNSAFE PRACTICES WHICH MAY RESULT IN PROPERTY DAMAGE, PRODUCT DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

THE UNIT MUST HAVE AN UNINTERRUPTED, UNBROKEN ELECTRICAL GROUND TO MINIMIZE THE POSSIBILITY OF PERSONAL INJURY IF AN ELECTRICAL FAULT SHOULD OCCUR. THE ELECTRICAL GROUND CIRCUIT MAY CONSIST OF AN APPROPRIATELY SIZED ELECTRICAL WIRE CONNECTING THE GROUND LUG IN THE UNIT CONTROL BOX TO THE BUILDING ELECTRICAL SERVICE PANEL. OTHER METHODS OF GROUNDING ARE PERMITTED IF PERFORMED IN ACCORDANCE WITH THE “NATIONAL ELECTRIC CODE” (NEC)/”AMERICAN NATIONAL STANDARDS INSTITUTE” (ANSI)/”NATIONAL FIRE PROTECTION ASSOCIATION” (NFPA) 70 AND LOCAL/STATE CODES. IN CANADA, ELECTRICAL GROUNDING IS TO BE IN ACCORDANCE WITH THE CANADIAN ELECTRIC CODE CSA C22.1. FAILURE TO OBSERVE THIS WARNING CAN RESULT IN ELECTRICAL SHOCK THAT CAN CAUSE PERSONAL INJURY.

WARNING

BEFORE SERVICING OR INSTALLING THIS EQUIPMENT, THE ELECTRICAL POWER TO THIS UNIT MUST BE IN THE “OFF” POSITION. CAUTION, MORE THAN ONE DISCONNECT MAY EXIST. FAILURE TO OBSERVE THIS WARNING MAY RESULT IN AN ELECTRICAL SHOCK THAT CAN CAUSE PERSONAL INJURY.

WARNING

DUE TO HIGH SYSTEM PRESSURE AND ELECTRICAL SHOCK POTENTIAL, INSTALLING AND THE SERVICING AIR CONDITIONING SYSTEMS CAN BE HAZARDOUS. ONLY TRAINED AND QUALIFIED PERSONNEL ARE PERMITTED TO INSTALL OR SERVICE THIS EQUIPMENT. OBSERVE ALL WARNINGS CONTAINED IN THIS MANUAL AND LABELS/TAGS ATTACHED TO THE EQUIPMENT.

IO-230F

2

08/04

 

 

Image 2
Contents Installation & Operating Instructions for Introduction Before Beginning InstallationReplacement Parts Checking Product ReceivedModel Identification Product DescriptionCFM Unit InspectionElectric Heat Location HKR InstallationElectrical Supply Wire and MOP DuctworkUSE Copper Conductors only Refrigerant LinesTXV Models Arpt and Aept Piping SizeEvaporator Coil Metering Devices Conversion to Downflow Aept Motor OrientationAept Motor Orientation ARUFor Arpt Aept model Insulation KitConversion to Horizontal Condensate RemovalAept Motor Achieving 2% LOW Leakage RateARUF/ARPF Motor Electric Heat CFMTwo Stage Heating Thermostat WiringHumidity Control RED Thermostats START-UP ProcedureRegular Maintenance

AEPT, ARPF, ARPT specifications

Goodman Manufacturing is a leading name in the air conditioning and heating industry, known for its commitment to high-quality products and innovative technologies. Among its esteemed lineup are the AEPT, ARPT, and ARPF series of heat pumps, which have garnered attention for their efficiency, reliability, and advanced features.

The Goodman AEPT series is designed for high efficiency and performance. These heat pumps utilize scroll compressor technology, which not only enhances their energy efficiency but also provides quieter operation compared to traditional compressors. With a SEER (Seasonal Energy Efficiency Ratio) rating that often exceeds 15, the AEPT series allows homeowners to significantly reduce their energy costs while enjoying optimal comfort throughout the year. Additionally, these units come equipped with a weather-resistant cabinet designed to withstand harsh outdoor conditions, ensuring durability and longevity.

The ARPT series takes innovation a step further by incorporating advanced refrigerant technology. Using R-410A refrigerant, these heat pumps operate with minimal environmental impact while providing robust heating and cooling capabilities. The ARPT units are equipped with a multi-speed ECM (Electronically Commutated Motor) blower motor that allows for improved airflow and enhanced humidity control, leading to a more comfortable indoor environment. The smart design of the ARPT series also emphasizes ease of installation and service, making it a preferred choice among HVAC professionals.

Finally, the Goodman ARPF series is engineered for versatility and performance in various climates. With a focus on user-friendly features, these heat pumps are designed to operate efficiently in both heating and cooling modes. The ARPF models come with digital thermostats that provide precise temperature control, ensuring that homes remain comfortable regardless of external weather conditions. Moreover, their advanced defrost controls allow for enhanced performance in colder climates, ensuring that homeowners can rely on their heat pumps even during extreme temperatures.

In summary, the Goodman AEPT, ARPT, and ARPF heat pump series showcase cutting-edge technology and innovative features focused on energy efficiency, environmental responsibility, and user comfort. These units not only promise durability and high performance but also ease of installation and maintenance, making them a smart investment for homeowners seeking reliable climate control solutions.